Trigger In mode provides higher level
of control to the user for displaying patterns. In this mode, the user determines
when to display the pattern by sending an external trigger signal to the DLPC3470
controller. The DLPC3470 controller outputs a Pattern Ready signal to let the user
know when DLPC3470 controller is ready to accept an external trigger signal.
- The DLPC3470 controller sets the Pattern Ready signal high
to denote that the DLPC3470 controller is ready to accept the Trigger In
signal.
- The user sends the external trigger input signal to the
DLPC3470 controller to begin the display of the next pattern with
tExposure (exposure time), tDarkPre and
tDarkPost (dark time).
- The Blue LED is configured to be on for each pattern.
- TRIG_OUT_1 (Pattern Set Trigger) is configured active high
polarity and will have a minimum pulse width of 20 microseconds. TRIG_OUT_1
delay (tD1) is configured with respect to external trigger input
(TRIG_IN).
- TRIG_OUT_2 (Pattern Trigger) is configured active high
polarity and stays active during the pattern exposure. TRIG_OUT_2 delay
(tD2) is configured with reference to the start of each
pattern exposure.