After the motor is confirmed to be stationary and after completing the motor initialization, the DRV10974 device begins to accelerate the motor. This acceleration is accomplished by applying a voltage to the motor at the appropriate drive state and increasing the rate of commutation without regard to the actual position of the motor (referred to as open-loop operation). The function of the open-loop operation is to drive the motor to a minimum speed so that the motor generates sufficient BEMF to allow the commutation control logic to drive the motor accurately.
The motor start-up profile can be configured using an external resistor to set the acceleration profile before transitioning to closed-loop operation. Figure 7-14 shows this acceleration profile. During closed-loop operation the RMP pin controls the closed-loop acceleration and deceleration. Table 7-2 lists the selectable acceleration parameters.
RMP SELECTION | RRMP [kΩ](1) | Accel2 [Hz/s2] | Accel1 [Hz/s] | CLOSED-LOOP-ACCELERATION TRANSITION TIME [s](2) | CLOSED-LOOP-DECELERATION TRANSITION TIME [s](3) |
---|---|---|---|---|---|
0 | 7.32 | 0.22 | 4.6 | 2.7 | 44 |
1 | 10.7 | 1.65 | 9.2 | 2.7 | 22 |
2 | 14.3 | 1.65 | 15 | 1 | 22 |
3 | 17.8 | 3.3 | 25 | 1 | 11 |
4 | 22.1 | 7 | 25 | 0.2 | 44 |
5 | 28 | 7 | 35 | 0.2 | 22 |
6 | 34 | 14 | 50 | 0.2 | 22 |
7 | 41.2 | 27 | 75 | 0.2 | 11 |
8 | 49.9 | 27 | 75 | 5.4 | 11 |
9 | 59 | 14 | 50 | 8 | 22 |
10 | 71.5 | 7 | 35 | 11 | 22 |
11 | 86.6 | 7 | 25 | 22 | 44 |
12 | 105 | 3.3 | 25 | 5.4 | 11 |
13 | 124 | 1.65 | 15 | 8 | 22 |
14 | 150 | 1.65 | 9.2 | 11 | 22 |
15 | 182 | 0.22 | 4.6 | 22 | 44 |