JAJSD22B March 2017 – December 2018 DRV8702D-Q1 , DRV8703D-Q1
PRODUCTION DATA.
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
FAULT status is shown in Figure 47 and described in Table 15.
Return to Summary Table.
Read only
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
FAULT | WDFLT | GDF | OCP | VM_UVFL | VCP_UVFL | OTSD | OTW |
R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b | R-0b |
Bit | Field | Type | Default | Description |
---|---|---|---|---|
7 | FAULT | R | 0b |
Logic OR of the FAULT status register excluding the OTW bit |
6 | WDFLT | R | 0b |
Watchdog time-out fault |
5 | GDF | R | 0b |
Indicates gate drive fault condition |
4 | OCP | R | 0b |
Indicates VDS monitor overcurrent fault condition |
3 | VM_UVFL | R | 0b |
Indicates VM undervoltage lockout fault condition |
2 | VCP_UVFL | R | 0b |
Indicates charge-pump undervoltage fault condition |
1 | OTSD | R | 0b |
Indicates overtemperature shutdown |
0 | OTW | R | 0b |
Indicates overtemperature warning |