over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
VCC | Supply voltage(2) | | 36 | V |
VID | Differential input voltage(3) | | ±36 | V |
VI | Input voltage range (either input) | –0.3 | 36 | V |
IK | Input current(5) | | –50 | mA |
VO | Output voltage | | 36 | V |
IO | Output current | | 20 | mA |
| Duration of output short circuit to ground(4) | Unlimited | |
TJ | Operating virtual-junction temperature | | 150 | °C |
| Case temperature for 60 s | FK package | | 260 | °C |
| Lead temperature 1.6 mm (1/16 in) from case for 60 s | J package | | 300 | °C |
Tstg | Storage temperature | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to network ground.
(3) Differential voltages are at xIN+ with respect to xIN–.
(4) Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
(5) Input current flows through parasitic diode to ground and will turn on parasitic transistors that will increase ICC and may cause output to be incorrect. Normal operation resumes when input is removed.