JAJSA30G November 2002 – May 2019 LM2733
PRODUCTION DATA.
Although internally compensated, the feedforward capacitor Cf is required for stability (see Figure 24). Adding this capacitor puts a zero in the loop response of the converter. Without it, the regulator loop can oscillate. The recommended frequency for the zero fz is approximately 8 kHz. Cf can be calculated using the formula: