JAJSIZ3Y September 1997 – April 2020 LM317
PRODUCTION DATA.
The current limit operation mode can be used to trickle charge a battery at a fixed current. ICHG = 1.25 V ÷ 24 Ω. VI should be greater than VBAT + 4.25 V. (1.25 V [VREF] + 3 V [headroom])