JAJSFD4A May 2018 – November 2018 LM5122ZA
PRODUCTION DATA.
The restart capacitor determines restart delay time tRD and hiccup mode off time tRES (see Figure 26). tRD must be greater than tSS(MAX). The minimum required value of CRES can be calculated at the low input voltage as follows:
A standard value of 0.47 µF is selected for CRES.