JAJSOX6 October   2023 LM74930-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1  Charge Pump
      2. 7.3.2  Dual Gate Control (DGATE, HGATE)
        1. 7.3.2.1 Load Disconnect Switch Control (HGATE, OUT)
        2. 7.3.2.2 Reverse Battery Protection (A, C, DGATE)
      3. 7.3.3  Overcurrent Protection (CS+, CS-, ILIM, IMON, TMR)
      4. 7.3.4  Overcurrent Protection with Circuit Breaker (ILIM, TMR)
      5. 7.3.5  Overcurrent Protection With Latch-Off
      6. 7.3.6  Short-Circuit Protection (ISCP)
        1. 7.3.6.1 Device Wake-Up With Output Short-Circuit Condition
      7. 7.3.7  Analog Current Monitor Output (IMON)
      8. 7.3.8  Overvoltage and Undervoltage Protection (OV, UVLO, OVCLAMP)
      9. 7.3.9  Disabling Reverse Current Blocking Functionality (MODE)
      10. 7.3.10 Device Functional Modes
        1. 7.3.10.1 Low Quiescent Current Shutdown Mode (EN)
  9. Applications and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application: 200-V Unsuppressed Load Dump Protection Application
      1. 8.2.1 Design Requirements for 200-V Unsuppressed Load Dump Protection
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1  VS Capacitance, Resistor R1 and Zener Clamp (DZ)
        2. 8.2.2.2  Charge Pump Capacitance VCAP
        3. 8.2.2.3  Input and Output Capacitance
        4. 8.2.2.4  Overvoltage and Undervoltage Protection Component Selection
        5. 8.2.2.5  Selection of Scaling Resistor (RSET) and Short-Circuit Protection Setting Resistor (RSCP)
        6. 8.2.2.6  Overcurrent Limit (ILIM), Circuit Breaker Timer (TMR), and Current Monitoring Output (IMON) Selection
        7. 8.2.2.7  Selection of Current Sense Resistor, RSNS
        8. 8.2.2.8  Hold-Up Capacitance
        9. 8.2.2.9  MOSFET Q1 Selection
        10. 8.2.2.10 MOSFET Q2 Selection
        11. 8.2.2.11 Input TVS Selection
      3. 8.2.3 Application Curves
    3. 8.3 Best Design Practices
    4. 8.4 Power Supply Recommendations
      1. 8.4.1 Transient Protection
      2. 8.4.2 TVS Selection for 12-V Battery Systems
      3. 8.4.3 TVS Selection for 24-V Battery Systems
    5. 8.5 Layout
      1. 8.5.1 Layout Guidelines
      2. 8.5.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Charge Pump

The charge pump supplies the voltage necessary to drive the external N-channel MOSFET. An external charge pump capacitor is placed between CAP and VS pins to provide energy to turn on the external MOSFET. In order for the charge pump to supply current to the external capacitor, the EN pin voltage must be above the specified input high threshold. When enabled the charge pump sources a charging current of 2.7-mA typical. If EN pin is pulled low, then the charge pump remains disabled. To ensure that the external MOSFET can be driven above its specified threshold voltage, the CAP to VS voltage must be above the undervoltage lockout threshold, typically 6.6 V, before the internal gate driver is enabled. Use Equation 1 to calculate the initial gate driver enable delay.

Equation 1. TDRV_EN=175μs+CVCAP×VVCAP_UVLOR2.7 mA

where

  • C(CAP) is the charge pump capacitance connected across VS and CAP pins
  • V(CAP_UVLOR) = 6.6 V (typical)

To remove any chatter on the gate drive approximately 1 V of hysteresis is added to the VCAP undervoltage lockout. The charge pump remains enabled until the CAP to VS voltage reaches 13.2 V, typically, at which point the charge pump is disabled decreasing the current draw on the VS pin. The charge pump remains disabled until the CAP to VS voltage is below to 12.2 V typically at which point the charge pump is enabled. The voltage between CAP and VS continue to charge and discharge between 12.2 V and 13.2 V as shown in Figure 7-1. By enabling and disabling the charge pump, the operating quiescent current of the LM74930-Q1 is reduced. When the charge pump is disabled it sinks 15 µA.

GUID-20231013-SS0I-TLJ1-QKQX-RL2D8QDW7T4M-low.svgFigure 7-1 Charge Pump Operation