JAJSGV2D January 2012 – September 2021 LMK01801
PRODUCTION DATA
When set, causes a SYNC event to occur when programming R4 to adjust digital delay values (this will cause a SYNC event for Bank B only) or R5 when adjusting divide values (this will cause a SYNC event for both Bank A and B).
The SYNC event will coincide with the LE uWire pin falling edge.
R3[26, 25] | Mode |
---|---|
0 | Manual SYNC |
1 | SYNC internally generated |