JAJSDF8B March 2017 – July 2019 LMK04616
PRODUCTION DATA.
The PLL2_AC_JUMPSTEP Register provides control of the PLL2 Amplitude Calibration step size. Back to Register Map.
BIT NO. | FIELD | TYPE | RESET | DESCRIPTION |
---|---|---|---|---|
[7:4] | RSRVD | - | - | Reserved. |
[3:0] | PLL2_AC_JUMP_STEP[3:0] | RW | 0xF | PLL2 IDAC Code Jump Step. When PLL2_FAST_ACAL is 1 then the IDACSET step value is set by PLL2_AC_JUMP_STEP. |