SNAS872 December 2024 LMR60410
PRODMIX
The LMR60410 uses soft start to prevent output voltage overshoots and large inrush currents during start-up. The soft-start time is fixed internally at 6ms (typical). The LMR60410 device operates correctly even if there is a voltage present on the output before activation.
To start-up the LMR60410 and initiate the soft-start sequence, the voltage applied to the VIN and EN pins must exceed VINUVLO(R) and VEN-TH(R) respectively. After these conditions are met, the soft-start sequence initiates and the output voltage reaches the set-point in 6ms (typical).