JAJSCZ0 February 2017 LMV551-Q1
PRODUCTION DATA.
The V+ pin should be bypassed to ground with a low-ESR capacitor.
The optimum placement is closest to the V+ and ground pins.
Ensure to minimize the loop area formed by the bypass capacitor connection between V+ and ground.
Connect the ground pin to the PCB ground plane at the pin of the device.