SNVSCC4A October   2023  – September 2024 LP5811

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Synchronous Boost Converter
        1. 6.3.1.1 Undervoltage Lockout
        2. 6.3.1.2 Enable and Soft Start
        3. 6.3.1.3 Switching Frequency
        4. 6.3.1.4 Current Limit Operation
        5. 6.3.1.5 Boost PWM Mode
        6. 6.3.1.6 Boost PFM Mode
      2. 6.3.2 Analog Dimming
      3. 6.3.3 PWM Dimming
      4. 6.3.4 Autonomous Animation Engine Control
        1. 6.3.4.1 Animation Engine Pattern
        2. 6.3.4.2 Sloper
        3. 6.3.4.3 Animation Engine Unit (AEU)
        4. 6.3.4.4 Animation Pause Unit (APU)
      5. 6.3.5 Protections and Diagnostics
        1. 6.3.5.1 Overvoltage Protection
        2. 6.3.5.2 Output Short-to-Ground Protection
        3. 6.3.5.3 LED Open Detections
        4. 6.3.5.4 LED Short Detections
        5. 6.3.5.5 Thermal Shutdown
    4. 6.4 Device Functional Modes
    5. 6.5 Programming
    6. 6.6 Register Maps
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Application
      2. 7.2.2 Design Parameters
      3. 7.2.3 Detailed Design Procedure
        1. 7.2.3.1 Inductor Selection
        2. 7.2.3.2 Output Capacitor Selection
        3. 7.2.3.3 Input Capacitor Selection
        4. 7.2.3.4 Program Procedure
        5. 7.2.3.5 Programming Example
      4. 7.2.4 Application Performance Plots
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Documentation Support
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)(1)
MIN MAX UNIT
Voltage range at terminals VIN, SW, VOUT –0.3 6 V
SW spike at 10 ns –0.7 8 V
SW spike at 1 ns –0.7 9 V
OUT0, OUT1, OUT2, OUT3 –0.3 6 V
EN, SCL, SDA, SYNC –0.3 6 V
TJ Junction temperature –40 150 °C
Tstg Storage temperature –65 150 °C
Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.