JAJSRP1D June   1980  – October 2023 MC3486

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Resistance Characteristics
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 ドキュメントの更新通知を受け取る方法
    2. 8.2 サポート・リソース
    3. 8.3 商標
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • NS|16
  • N|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended ranges of common-mode input voltage, supply voltage, and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN MAX UNIT
VIT+ Differential input high-threshold voltage VO = 2.7 V, IO = -0.4 mA 0.2 V
VIT - Differential input low-threshold voltage VO = 0.5 V, IO = -8 mA - 0.2(1) V
VIK Enable-input clamp voltage II = -10 mA -1.5 V
VOH High-level output voltage VID = 0.4 V, See Note 4 and Figure 6-1 IO = -0.4 mA, 2.7 V
VOL Low-level output voltage VID = - 0.4 V, See Note 4 and Figure 6-1 IO = 8 mA, 0.5 V
IOZ High-impedance-state output current VIL = 0.8 V, VID = -3 V, VO = 2.7 V 40 μA
VIL = 0.8 V, VID = 3 V, VO = 0.5 V -40
IIB Differential-input bias current VCC = 0 V or 2.25 V, Other inputs at 0 V VI = -10 V -3.25 mA
VI = - 3 V -1.5
VI = 3 V 1.5
VI = 10 V 3.25
IIH High-level enable input current VI = 2.25 V 100 μA
VI = 2.7 V 20
IIL Low-level enable input current VI = - 0.5 V -100 μA
IOS Short-circuit output current VID = 3 v, VO = 0, See Note 5 -15 -100 mA
ICC Supply current VIL = 0 85 mA
The algebraic convention, in which the least positive (most negative) limit is designated as minimum, is used in this data sheet for threshold voltages only.
Refer to ANSI Standards TIA/EIA-422-B and TIA/EIA-423-B for exact conditions.
Only one output should be shorted at a time.