SLLSFX9 December 2024 MCF8316D
PRODUCTION DATA
MCF8316D provides a configurable VM undervoltage protection. The VM level at which MCF8316D triggers the undervoltage fault is set by MIN_VM_MOTOR and the fault response to VM undervoltage is set by MIN_VM_MODE. If MIN_VM_MODE is set to 0b, VM undervoltage fault (at MIN_VM_MOTOR) is latched and the FETs are in Hi-Z until the fault condition is cleared by writing 1b to CLR_FLT bit. If MIN_VM_MODE is set to 1b, VM undervoltage fault (at MIN_VM_MOTOR) automatically clears and the device starts motor operation once VM > (MIN_VM_MOTOR + VOLTAGE_HYSTERESIS).