SLLSFX9 December   2024 MCF8316D

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Characteristics of the SDA and SCL bus for Standard and Fast mode
    7. 5.7 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1  Output Stage
      2. 6.3.2  Device Interface
        1. 6.3.2.1 Interface - Control and Monitoring
        2. 6.3.2.2 I2C Interface
      3. 6.3.3  Step-Down Mixed-Mode Buck Regulator
        1. 6.3.3.1 Buck in Inductor Mode
        2. 6.3.3.2 Buck in Resistor mode
        3. 6.3.3.3 Buck Regulator with External LDO
        4. 6.3.3.4 AVDD Power Sequencing from Buck Regulator
        5. 6.3.3.5 Mixed Mode Buck Operation and Control
      4. 6.3.4  AVDD Linear Voltage Regulator
      5. 6.3.5  Charge Pump
      6. 6.3.6  Slew Rate Control
      7. 6.3.7  Cross Conduction (Dead Time)
      8. 6.3.8  Motor Control Input Sources
        1. 6.3.8.1 Analog-Mode Motor Control
        2. 6.3.8.2 PWM-Mode Motor Control
        3. 6.3.8.3 I2C-based Motor Control
        4. 6.3.8.4 Frequency-Mode Motor Control
        5. 6.3.8.5 Input Reference Profiles
          1. 6.3.8.5.1 Linear Control Profiles
          2. 6.3.8.5.2 Staircase Control Profiles
          3. 6.3.8.5.3 Forward-Reverse Profiles
          4. 6.3.8.5.4 Multi-Reference Mode Operation
          5. 6.3.8.5.5 Input Reference Transfer Function without Profiler
      9. 6.3.9  Starting the Motor Under Different Initial Conditions
        1. 6.3.9.1 Case 1 – Motor is Stationary
        2. 6.3.9.2 Case 2 – Motor is Spinning in the Forward Direction
        3. 6.3.9.3 Case 3 – Motor is Spinning in the Reverse Direction
      10. 6.3.10 Motor Start Sequence (MSS)
        1. 6.3.10.1 Initial Speed Detect (ISD)
        2. 6.3.10.2 Motor Resynchronization
        3. 6.3.10.3 Reverse Drive
          1. 6.3.10.3.1 Reverse Drive Tuning
        4. 6.3.10.4 Motor Start-up
          1. 6.3.10.4.1 Align
          2. 6.3.10.4.2 Double Align
          3. 6.3.10.4.3 Initial Position Detection (IPD)
            1. 6.3.10.4.3.1 IPD Operation
            2. 6.3.10.4.3.2 IPD Release Mode
            3. 6.3.10.4.3.3 IPD Advance Angle
          4. 6.3.10.4.4 Slow First Cycle Startup
          5. 6.3.10.4.5 Open Loop
          6. 6.3.10.4.6 Transition from Open to Closed Loop
      11. 6.3.11 Closed Loop Operation
        1. 6.3.11.1 Closed Loop Acceleration/Deceleration Slew Rate
        2. 6.3.11.2 Speed PI Control
        3. 6.3.11.3 Current PI Control
        4. 6.3.11.4 Power Control Mode
        5. 6.3.11.5 Current (Torque) Control Mode
        6. 6.3.11.6 Modulation Index Control
        7. 6.3.11.7 Overmodulation
        8. 6.3.11.8 Motor Speed Limit
        9. 6.3.11.9 Input DC Power Limit
      12. 6.3.12 Flux Weakening Control
      13. 6.3.13 Motor Parameters
        1. 6.3.13.1 Motor Resistance
        2. 6.3.13.2 Motor Inductance
        3. 6.3.13.3 Motor Back-EMF constant
      14. 6.3.14 Motor Parameter Extraction Tool (MPET)
      15. 6.3.15 Anti-Voltage Surge (AVS)
      16. 6.3.16 Active Braking
      17. 6.3.17 Output PWM Switching Frequency
      18. 6.3.18 PWM Dithering
      19. 6.3.19 PWM Modulation Schemes
      20. 6.3.20 Dead Time Compensation
      21. 6.3.21 Motor Stop Options
        1. 6.3.21.1 Coast (Hi-Z) Mode
        2. 6.3.21.2 Recirculation Mode
        3. 6.3.21.3 Low-Side Braking
        4. 6.3.21.4 High-Side Braking
        5. 6.3.21.5 Active Spin-Down
      22. 6.3.22 Align Braking
      23. 6.3.23 FG Configuration
        1. 6.3.23.1 FG Output Frequency
        2. 6.3.23.2 FG during Open and Closed Loop States
        3. 6.3.23.3 FG during Fault and Idle States
      24. 6.3.24 Protections
        1. 6.3.24.1  VM Supply Undervoltage Lockout
        2. 6.3.24.2  AVDD Undervoltage Lockout (AVDD_UV)
        3. 6.3.24.3  BUCK Under Voltage Lockout (BUCK_UV)
        4. 6.3.24.4  VCP Charge Pump Undervoltage Lockout (CPUV)
        5. 6.3.24.5  Overvoltage Protection (OVP)
        6. 6.3.24.6  Overcurrent Protection (OCP)
          1. 6.3.24.6.1 OCP Latched Shutdown (OCP_MODE = 00b)
          2. 6.3.24.6.2 OCP Automatic Retry (OCP_MODE = 01b)
        7. 6.3.24.7  Buck Overcurrent Protection
        8. 6.3.24.8  Hardware Lock Detection Current Limit (HW_LOCK_ILIMIT)
          1. 6.3.24.8.1 HW_LOCK_ILIMIT Latched Shutdown
          2. 6.3.24.8.2 HW_LOCK_ILIMIT Automatic Recovery
          3. 6.3.24.8.3 HW_LOCK_ILIMIT Report Only
          4. 6.3.24.8.4 HW_LOCK_ILIMIT Disabled
        9. 6.3.24.9  Lock Detection Current Limit (LOCK_ILIMIT)
          1. 6.3.24.9.1 LOCK_ILIMIT Latched Shutdown
          2. 6.3.24.9.2 LOCK_ILIMIT Automatic Recovery
          3. 6.3.24.9.3 LOCK_ILIMIT Report Only
          4. 6.3.24.9.4 LOCK_ILIMIT Disabled
        10. 6.3.24.10 Motor Lock Detection
          1. 6.3.24.10.1 Lock 1: Abnormal Speed (ABN_SPEED)
          2. 6.3.24.10.2 Lock 2: Abnormal BEMF (ABN_BEMF)
          3. 6.3.24.10.3 Lock3: No-Motor Fault (NO_MTR)
        11. 6.3.24.11 Motor Lock (MTR_LCK)
          1. 6.3.24.11.1 MTR_LCK Latched Shutdown
          2. 6.3.24.11.2 MTR_LCK Automatic Recovery
          3. 6.3.24.11.3 MTR_LCK Report Only
          4. 6.3.24.11.4 MTR_LCK Disabled
        12. 6.3.24.12 EEPROM Fault
        13. 6.3.24.13 I2C CRC Fault
        14. 6.3.24.14 Minimum VM (Undervoltage) Protection
        15. 6.3.24.15 Maximum VM (Overvoltage) Protection
        16. 6.3.24.16 MPET Faults
        17. 6.3.24.17 IPD Faults
        18. 6.3.24.18 FET Thermal Warning (OTW)
        19. 6.3.24.19 FET Thermal Shutdown (TSD_FET)
    4. 6.4 Device Functional Modes
      1. 6.4.1 Functional Modes
        1. 6.4.1.1 Sleep Mode
        2. 6.4.1.2 Standby Mode
        3. 6.4.1.3 Fault Reset (CLR_FLT)
    5. 6.5 External Interface
      1. 6.5.1 DRVOFF Functionality
      2. 6.5.2 DAC outputs
      3. 6.5.3 Current Sense Output
      4. 6.5.4 Oscillator Source
        1. 6.5.4.1 External Clock Source
      5. 6.5.5 External Watchdog
    6. 6.6 EEPROM access and I2C interface
      1. 6.6.1 EEPROM Access
        1. 6.6.1.1 EEPROM Write
        2. 6.6.1.2 EEPROM Read
        3. 6.6.1.3 EEPROM Security
      2. 6.6.2 I2C Serial Interface
        1. 6.6.2.1 I2C Data Word
        2. 6.6.2.2 I2C Write Transaction
        3. 6.6.2.3 I2C Read Transaction
        4. 6.6.2.4 I2C Communication Protocol Packet Examples
        5. 6.6.2.5 I2C Clock Stretching
        6. 6.6.2.6 CRC Byte Calculation
    7. 6.7 EEPROM (Non-Volatile) Register Map
      1. 6.7.1 Algorithm_Configuration Registers
      2. 6.7.2 Fault_Configuration Registers
      3. 6.7.3 Hardware_Configuration Registers
      4. 6.7.4 Internal_Algorithm_Configuration Registers
    8. 6.8 RAM (Volatile) Register Map
      1. 6.8.1 Fault_Status Registers
      2. 6.8.2 System_Status Registers
      3. 6.8.3 Device_Control Registers
      4. 6.8.4 Algorithm_Control Registers
      5. 6.8.5 Algorithm_Variables Registers
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Applications
      1. 7.2.1 Application Curves
        1. 7.2.1.1 Motor startup
        2. 7.2.1.2 MPET
        3. 7.2.1.3 Dead time compensation
        4. 7.2.1.4 Auto handoff
        5. 7.2.1.5 Anti voltage surge (AVS)
        6. 7.2.1.6 Real time variable tracking using DACOUT
  9. Power Supply Recommendations
    1. 8.1 Bulk Capacitance
  10. Layout
    1. 9.1 Layout Guidelines
    2. 9.2 Layout Example
    3. 9.3 Thermal Considerations
      1. 9.3.1 Power Dissipation
  11. 10Device and Documentation Support
    1. 10.1 Support Resources
    2. 10.2 Trademarks
    3. 10.3 Electrostatic Discharge Caution
    4. 10.4 Glossary
  12. 11Mechanical, Packaging, and Orderable Information
  13. 12Revision History

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ

PWM Dithering

MCF8316D provides the option of PWM dithering to reduce the EMI generated by MOSFET switching - when enabled, the PWM switching frequency is varied continuously (within a user configured frequency range) around the PWM_FREQ_OUT setting to spread the EMI energy across the frequency spectrum and reduce the EMI peak values. The user configured frequency range for PWM dithering is set by PWM_DITHER_DEPTH; setting PWM_DITHER_DEPTH to 0x0 disables PWM dithering. PWM_DITHER_DEPTH provides ±5%, ±7.5% and ±10% frequency spread options. When PWM_FREQ_OUT is set to 25kHz and PWM_DITHER_DEPTH is set to ±10%, the PWM switching frequency applied to the MOSFETs continuously varies between 22.5kHz (25kHz-10%) and 27.5kHz (25kHz+10%), thereby reducing the EMI peaks at multiples of 25kHz. PWM dithering is available in two modes - random or triangular (configured by PWM_DITHER_MODE). In random dithering, the PWM switching frequency is continuously varied randomly within the range set by PWM_FREQ_OUT and PWM_DITHER_DEPTH. In triangular dithering, the PWM switching frequency is varied at user configured slew rate (configured by PWM_DITHER_STEP) as shown in Figure 6-51.

MCF8316D Triangular PWM Dithering Figure 6-51 Triangular PWM Dithering

The PWM switching frequency slew rate (PWM_DITHER_SLEW in Figure 6-51) is set as shown in Equation 10.

Equation 10. PWM_DITHER_SLEW (kHz/s) = PWM_DITHER_STEP * SLEW_SCALING FACTOR

SLEW_SCALING FACTOR varies with PWM switching frequency as listed in Table 6-5.

Table 6-5 SLEW_SCALING FACTOR vs PWM switching frequency
PWM switching frequency (kHz) SLEW_SCALING FACTOR
10 1
15 2.25
20 2
25 3.125
30 4.5
35 3.0625
40 4
45 5.0625
50 6.25
55 7.5625
60 9