The MCT8314Z device also has an open-drain FG signal that can be used for closed-loop speed control of a BLDC motor. This signal includes the information of all three Hall-elements inputs as shown in Section 7.3.14. In the MCT8314ZS (SPI variant), FG can be configured to be a different division factor of Hall signals as shown in Section 7.3.14. In the MCT8314ZH (Hardware variant), the FGSEL/LOCK_DET_TIME pin selects between 3x (FGOUT_SEL = 00b) or 1x (FGOUT_SEL = 01b) commutation frequencies as shown in Table 7-8.
Setting | FGSEL/LOCK_DET_TIME Pin (Hardware Variant) | FG Output Commutation Frequency | tMTR_ LOCK |
---|---|---|---|
Setting-1 | Connected to AGND | 3x commutation frequency (FGOUT_SEL = 00b) | 300 ms |
Setting-2 | Connected to AGND with RMODE1 | 500 ms | |
Setting-3 | Connected to AGND with RMODE2 | 1000 ms | |
Setting-4 | Hi-Z | 5000 ms | |
Setting-5 | Connected to AVDD with RMODE2 | 1x commutation frequency (FGOUT_SEL = 01b) | 300 ms |
Setting-6 | Connected to AVDD with RMODE1 | 500 ms | |
Setting-7 | Connected to AVDD | 1000 ms |