over operating free-air temperature range (unless otherwise noted).(1)
|
MIN |
MAX |
UNIT |
VS |
Supply voltage,
VS = (V+) – (V–) |
|
40 |
V |
|
Input voltage |
(V–) – 0.5 |
(V+) +
0.5 |
V |
|
Input current (all pins
except power-supply pins) |
|
±10 |
mA |
|
Output short-circuit(2) |
Continuous |
|
TA |
Operating
temperature |
–55 |
125 |
°C |
TJ |
Junction temperature |
|
150 |
°C |
Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause permanent
device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under
Recommended Operating Conditions. If used outside the Recommended
Operating Conditions but within the Absolute Maximum Ratings, the
device may not be fully functional, and this may affect device reliability,
functionality, performance, and shorten the device lifetime.
(2) Short-circuit to VS/2 (ground in symmetrical dual supply setups), one amplifier per package.