The internal power dissipation of any amplifier causes the junction temperature (TJ) to rise. This phenomenon is called self heating. To prevent damage from overheating, the OPA928 has a thermal protection feature.
This thermal protection works by monitoring the temperature of the output stage and turning off the op amp output drive for temperatures above approximately 180°C. Thermal protection forces the output to a high-impedance state. The OPA928 is also designed with approximately 30°C of thermal hysteresis. The OPA928 returns to normal operation when the output stage temperature reaches a safe operating temperature of approximately 150°C.