JAJSV92M October   1995  – August 2024 SN54AHC573 , SN74AHC573

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Electrical Characteristics
    6. 5.6  Timing Requirements, VCC = 3.3 V ± 0.3 V
    7. 5.7  Timing Requirements, VCC = 5 V ± 0.5 V
    8. 5.8  Switching Characteristics, VCC = 3.3 V ± 0.3 V
    9. 5.9  Switching Characteristics, VCC = 5 V ± 0.5 V
    10. 5.10 Noise Characteristics
    11. 5.11 Operating Characteristics
    12. 5.12 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Related Links
    2. 9.2 Trademarks
    3. 9.3 静電気放電に関する注意事項
    4. 9.4 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • W|20
  • J|20
  • FK|20
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETERTEST CONDITIONSVCCTA = 25°CSN54AHC573SN74AHC573–40°C to 125°C
SN74AHC573
UNIT
MINTYPMAXMINMAXMINMAXMINMAX
VOHIOH = −50 µA2 V1.921.91.91.9V
3 V2.932.92.92.9
4.5 V4.44.54.44.44.4
IOH = −4 mA3 V2.582.482.482.48
IOH = −8 mA4.5 V3.943.83.83.8V
VOLIOL = 50 µA2 V0.10.10.10.1
3 V0.10.10.10.1
4.5 V0.10.10.10.1
IOL = 4 mA3 V0.360.50.440.44
IOL = 8 mA4.5 V0.360.50.440.44
IIVI = 5.5 V or GND0 V to
5.5 V
±0.1±1(1)±1±1µA
IOZVI = VIL or VIH,
VO = VCC or GND
5.5 V±0.25±2.5±2.5±2.5µA
ICCVI = VCC or GND,IO = 05.5 V4404040µA
CiVI = VCC or GND5 V2.5101010pF
CoVO = VCC or GND5 V3.5pF
On products compliant to MIL-PRF-38535, this parameter is not production tested at VCC = 0 V.