JAJSU17B October   2004  – March 2024 SN74AC240-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics, VCC = 3.3 V ± 0.3 V
    6. 5.6 Switching Characteristics, VCC = 5 V ± 0.5 V
    7. 5.7 Operating Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Power Supply Recommendations
    2. 8.2 Layout
      1. 8.2.1 Layout Guidelines
      2. 8.2.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support (Analog)
      1. 9.1.1 Related Documentation
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PW|20
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS VCC TA = 25°C TA = −40°C TO 125°C TA = −40°C TO 85°C UNIT
MIN TYP MAX MIN MAX MIN MAX
VOH IOH = −50 µA 3 V 2.9 2.9 2.9 V
4.5 V 4.4 4.4 4.4
5.5 V 5.4 5.4 5.4
IOH = −12 mA 3 V 2.56 2.4 2.46
IOH = −24 mA 4.5 V 3.86 3.7 3.76
5.5 V 4.86 4.7 4.76
IOH = −50 mA(1) 5.5 V 3.85
IOH = −75 mA(1) 5.5 V 3.85
VOL IOL = 50 µA 3 V 0.1 0.1 0.1 V
4.5 V 0.1 0.1 0.1
5.5 V 0.1 0.1 0.1
IOL = 12 mA 3 V 0.36 0.5 0.44
IOL = 24 mA 4.5 V 0.36 0.5 0.44
5.5 V 0.36 0.5 0.44
IOL = 50 mA(1) 5.5 V 1.65
IOL = 75 mA(1) 5.5 V 1.65
II Data inputs VI = VCC or GND 5.5 V ±0.1 ±1 ±1 µA
Control inputs VI = VCC or GND ±0.1 ±1 ±1
IOZ (2) V= = VCC or GND, V(OE) = VIL or VIH 5.5 V ±0.25 ±5 ±2.5 µA
ICC VI = VCC or GND, IO = 0 5.5 V 4 80 40 µA
Ci VI = VCC or GND 5 V 2.5 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.