SCLS373N May   1996  – July 2024 SN74AHC595

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Electrical Characteristics
    6. 5.6  Timing Requirements: VCC = 3.3 V ± 0.3 V
    7. 5.7  Timing Requirements: VCC = 5 V ± 0.5 V
    8. 5.8  Switching Characteristics: VCC = 3.3 V ± 0.3 V
    9. 5.9  Switching Characteristics: VCC = 5 V ± 0.5 V
    10. 5.10 Operating Characteristics
    11. 5.11 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DB|16
  • PW|16
  • BQB|16
  • N|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted) (1)
PARAMETERTEST CONDITIONSVCCMINTYPMAXUNIT
VOHIOH = –50 µATA = 25°C2 V1.92V
TA = –40°C to 85°C1.9
TA = –40°C to 125°C Recommended1.9
IOH = –50 µATA = 25°C3 V2.93
TA = –40°C to 85°C2.9
TA = –40°C to 125°C Recommended2.9
IOH = –50 µATA = 25°C4.5 V4.44.5
TA = –40°C to 85°C4.4
TA = –40°C to 125°C Recommended4.4
IOH = –4 mATA = 25°C3 V2.58
TA = –40°C to 85°C2.48
TA = –40°C to 125°C Recommended2.48
IOH = –8 mATA = 25°C4.5 V3.94
TA = –40°C to 85°C3.8
TA = –40°C to 125°C Recommended3.8
VOLIOL = 50 µATA = 25°C2 V0.1V
TA = –40°C to 85°C0.1
TA = –40°C to 125°C Recommended0.1
IOL = 50 µATA = 25°C3 V0.1
TA = –40°C to 85°C0.1
TA = –40°C to 125°C Recommended0.1
IOL = 50 µATA = 25°C4.5 V0.1
TA = –40°C to 85°C0.1
TA = –40°C to 125°C Recommended0.1
IOL = 4 mATA = 25°C3 V0.36
TA = –40°C to 85°C0.44
TA = –40°C to 125°C Recommended0.44
IOL = 8 mATA = 25°C4.5 V0.36
TA = –40°C to 85°C0.44
TA = –40°C to 125°C Recommended0.44
IIVI = 5.5 V or GNDTA = 25°C0 V to 5.5 V±0.1µA
TA = –40°C to 85°C±1
TA = –40°C to 125°C Recommended±1
IOZVI = VCC or GND,
VO = VCC or GND,
OE = VIH or VIL,
QA – QHTA = 25°C5.5 V±0.25μA
TA = –40°C to 85°C±2.5
TA = –40°C to 125°C Recommended±2.5
ICCVI = VCC or GND,IO = 0TA = 25°C5.5 V4µA
TA = –40°C to 85°C40
TA = –40°C to 125°C Recommended40
CiVI = VCC or GNDTA = 25°C5 V310pF
TA = –40°C TO 85°C10
COVO = VCC or GND,TA = 25°C5 V5.5pF
On products compliant to MIL-PRF-38535, this parameter is not production tested at VCC = 0 V.