JAJSRE0R March   1996  – February 2024 SN74AHCT1G14

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Thermal Information
    4. 5.4 Electrical Characteristics
    5. 5.5 Switching Characteristics
    6. 5.6 Operating Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
        1. 8.2.1.1 Power Considerations
        2. 8.2.1.2 Input Considerations
        3. 8.2.1.3 Output Considerations
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support (Analog)
      1. 9.1.1 Related Documentation
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • DBV|5
  • DCK|5
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over operating free-air temperature range (unless otherwise noted) (1)
PARAMETER TEST CONDITIONS VCC MIN TYP MAX UNIT
VT+ Positive-going input threshold voltage TA = 25°C 4.5 V 0.9 2 V
TA = –40°C to 85°C 0.9
TA = –40°C to 125°C 0.9 2
TA = 25°C 5.5 V 1.1 2
TA = –40°C to 85°C 1.1
TA = –40°C to 125°C 1.1 2
VT– Negative-going input threshold voltage TA = 25°C 4.5 V 0.5 1.6 V
TA = –40°C to 85°C 0.5
TA = –40°C to 125°C 0.5 1.6
TA = 25°C 5.5 V 0.6 1.5
TA = –40°C to 85°C 0.6
TA = –40°C to 125°C 0.6 1.5
ΔVT Hysteresis (VT+ – VT-) TA = 25°C 4.5 V 0.4 1.4 V
TA = –40°C to 85°C 0.4
TA = –40°C to 125°C 0.4 1.4
TA = 25°C 5.5 V 0.5 1.6
TA = –40°C to 85°C 0.4
TA = –40°C to 125°C 0.5 1.6
VOH High level output voltage IOH = –50 mA TA = 25°C 4.5 V 4.4 4.5 V
TA = –40°C to 85°C 4.4
TA = –40°C to 125°C 4.4
IOH = –8 mA TA = 25°C 3.94
TA = –40°C to 85°C 3.88
TA = –40°C to 125°C 3.7
VOL Low level output voltage IOL = 50 mA TA = 25°C 4.5 V 0.1 V
TA = –40°C to 85°C 0.1
TA = –40°C to 125°C 0.1
IOL = 8 mA TA = 25°C 0.36
TA = –40°C to 85°C 0.44
TA = –40°C to 125°C 0.55
II Input leakage current VI = 5.5 V or GND TA = 25°C 0 V to 5.5 V ±0.1 µA
TA = –40°C to 85°C ±1
TA = –40°C to 125°C ±1
ICC Supply current VI = VCC or GND, IO = 0 TA = 25°C 5.5 V 1 µA
TA = –40°C to 85°C 10
TA = –40°C to 125°C 10
Ci Input Capacitance VI = VCC or GND TA = 25°C 5 V 2 10 pF
TA = –40°C to 85°C 10
TA = –40°C to 125°C 10
Recommended TA = –40°C to 125°C