JAJSUR4G August   2003  – September 2024 SN74LV4051A-Q1

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Thermal Information: SN74LV4051A-Q1
    4. 5.4 Recommended Operating Conditions
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Characteristics VCC = 2.5 V ± 0.2 V
    7. 5.7 Timing Characteristics VCC = 3.3 V ± 0.3 V
    8. 5.8 Timing Characteristics VCC = 5 V ± 0.5 V
    9. 5.9 AC Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PW|16
  • DYY|16
  • DW|16
  • D|16
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER Condition TA VCC MIN TYP MAX UNIT
rON ON-state switch resistance IT = 2 mA,
VI = VCC or GND,
VINH = VIL
25°C 1.65 V 60 150
–40°C to 85°C 225
–40°C to 125°C 225
25°C 2.3 V 38 180
–40°C to 85°C 225
–40°C to 125°C 225
25°C 3 V 30 150
–40°C to 85°C 190
–40°C to 125°C 190
25°C 4.5 V 22 75
–40°C to 85°C 100
–40°C to 125°C 100
rON(p) Peak ON-state resistance IT = 2 mA,
VI = GND to VCC,
VINH = VIL
25°C 1.65 V 220 600
–40°C to 85°C 700
–40°C to 125°C 700
25°C 2.3 V 113 500
–40°C to 85°C 600
–40°C to 125°C 600
25°C 3 V 54 180
–40°C to 85°C 225
–40°C to 125°C 225
25°C 4.5 V 31 100
–40°C to 85°C 125
–40°C to 125°C 125
ΔrON Difference in ON-state resistance between switches IT = 2 mA,
VI = GND to VCC,
VINH = VIL
25°C 1.65 V
–40°C to 85°C
–40°C to 85°C
–40°C to 85°C 2.3 V 2.1 30
–40°C to 85°C 40
–40°C to 125°C 40
25°C 3 V 1.4 20
–40°C to 85°C 30
–40°C to 125°C 30
25°C 4.5 V 1.3 15
–40°C to 85°C 20
–40°C to 125°C 20
IIH 
IIL
Control input current VI = 5.5 V or GND 25°C 0 to 5.5 V -0.1 0.1 µA
–40°C to 85°C -1 1
–40°C to 125°C -2 2
IS(off) OFF-state switch leakage current VI = VCC and VO = GND,
or VI = GND and VO = VCC,
VINH = VIH
25°C 5.5 V -0.1 0.1 µA
–40°C to 85°C -1 1
–40°C to 125°C -2 2
IS(on) ON-state switch leakage current VI = VCC or GND,
VINH = VIL
25°C 5.5 V -0.1 0.1 µA
–40°C to 85°C -1 1
–40°C to 125°C -2 2
ICC Supply current VI = VCC or GND
VINH = 0 V
25°C 5.5 V µA
–40°C to 85°C 20
–40°C to 125°C 40
CIC Control input capacitance f = 10 MHz 25°C 3.3 V 2 pF
CIS Common terminal capacitance f = 10 MHz 25°C 3.3 V 23.4 pF
COS Switch ternminal capacitance f = 10 MHz 25°C 3.3 V 5.7 pF
CF Feedthrough capacitance f = 10 MHz 25°C 3.3 V 0.5 pF
CPD Power dissipation capacitance CL = 50 pF, f = 10 MHz 25°C 3.3 V 5.9 pF