JAJSRO6D September   1991  – October 2023 SN75ALS175

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Dissipation Rating Table
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Resistance Characteristics
    5. 5.5 Electrical Characteristics
    6. 5.6 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Device Functional Modes
  9. Device and Documentation Support
    1. 8.1 ドキュメントの更新通知を受け取る方法
    2. 8.2 サポート・リソース
    3. 8.3 Trademarks
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • NS|16
  • N|16
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended ranges of common-mode input voltage, supply voltage and operating free-air temperature (unless otherwise noted) (see Note 3)
PARAMETER TEST CONDITIONS MIN TYP (1) MAX UNIT
VIT+ Positive-going input threshold voltage 200 mV
VIT- Negative-going input threshold voltage -200 (2) mV
Vhys Hysteresis voltage (VIT+ - VIT-) 50 mV
VIK Enable-input clamp voltage II = -18 mA -1.5 V
VOH High-level output voltage VID = 200 mV, IOH = -400 μA, See Figure 6-1 2.7 V
VOL Low-level output voltage VID = -200 mV, IOL = 8 mA, See Figure 6-1 0.45 V
IOZ High-impedance-state output current VO = 0.4 V to 2.4 V ±20 μA
II Line input current Other input at 0 V, See Note 3 VI = 12 V 1 mA
VI = -7 V -0.8
IIH High-level enable-input current VIH(E) = 2.7 V 20 μA
IIL Low-level enable-input current VIL(E) = 0.4 V -100 μA
ri Input resistance 12
IOS Short-circuit output current VO = 0 -15 -85 mA
ICC Suply current (total package) No load, Outputs enabled 16 24 mA
No load, Outputs disabled 18 27
All typical values are at VCC = 5 V, TA = 25°C.
The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold voltage levels only.
Refer to ANSI Standard RS-485 for exact conditions.