7.2 ESD Ratings
PARAMETER |
DEFINITION |
MIN |
MAX |
UNIT |
VESD(1) |
Human Body Model (HBM), ESD Stress Voltage(2) |
All Terminals |
|
4000 |
V |
Charged Device Model (CDM) ESD Stress Voltage(3) |
All Terminals |
|
1500 |
V |
(1) Electrostatic discharge (ESD) to measure device sensitivity/immunity to damage caused by assembly line electrostatic discharges into the device.
(2) Level listed above is the passing level per ANSI/ESDA/JEDEC JS-001. JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Terminals listed as 250 V may actually have higher performance.