JAJSV04A July   2024  – November 2024 TCAN1043N-Q1

ADVANCE INFORMATION  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  ESD Ratings - IEC Specifications
    4. 5.4  Recommended Operating Conditions
    5. 5.5  Thermal Information
    6. 5.6  Power Dissipation Ratings
    7. 5.7  Power Supply Characteristics
    8. 5.8  Electrical Characteristics
    9. 5.9  Timing Requirements
    10. 5.10 Switching Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Supply Pins
        1. 7.3.1.1 VSUP Pin
        2. 7.3.1.2 VCC Pin
        3. 7.3.1.3 VIO Pin
      2. 7.3.2 Digital Inputs and Outputs
        1. 7.3.2.1 TXD Pin
        2. 7.3.2.2 RXD Pin
        3. 7.3.2.3 nFAULT Pin
        4. 7.3.2.4 EN Pin
        5. 7.3.2.5 nSTB Pin
      3. 7.3.3 GND
      4. 7.3.4 INH Pin
      5. 7.3.5 WAKE Pin
      6. 7.3.6 CAN Bus Pins
      7. 7.3.7 Faults
        1. 7.3.7.1 Internal and External Fault Indicators
          1. 7.3.7.1.1 Power-Up (PWRON Flag)
          2. 7.3.7.1.2 Wake-Up Request (WAKERQ Flag)
          3. 7.3.7.1.3 Undervoltage Faults
            1. 7.3.7.1.3.1 Undervoltage on VSUP
            2. 7.3.7.1.3.2 Undervoltage on VCC
            3. 7.3.7.1.3.3 Undervoltage on VIO
          4. 7.3.7.1.4 CAN Bus Fault (CBF Flag)
          5. 7.3.7.1.5 TXD Dominant State Timeout (TXDDTO Flag)
          6. 7.3.7.1.6 TXD Shorted to RXD Fault (TXDRXD Flag)
          7. 7.3.7.1.7 CAN Bus Dominant Fault (CANDOM Flag)
      8. 7.3.8 Local Faults
        1. 7.3.8.1 TXD Dominant Timeout (TXD DTO)
        2. 7.3.8.2 Thermal Shutdown (TSD)
        3. 7.3.8.3 Undervoltage Lockout (UVLO)
        4. 7.3.8.4 Unpowered Devices
        5. 7.3.8.5 Floating Terminals
        6. 7.3.8.6 CAN Bus Short-Circuit Current Limiting
    4. 7.4 Device Functional Modes
      1. 7.4.1 Operating Mode Description
        1. 7.4.1.1 Normal Mode
        2. 7.4.1.2 Silent Mode
        3. 7.4.1.3 Standby Mode
        4. 7.4.1.4 Go-To-Sleep Mode
        5. 7.4.1.5 Sleep Mode
          1. 7.4.1.5.1 Remote Wake Request via Wake-Up Pattern (WUP)
          2. 7.4.1.5.2 Local Wake-Up (LWU) via WAKE Input Terminal
      2. 7.4.2 CAN Transceiver
        1. 7.4.2.1 CAN Transceiver Operation
          1. 7.4.2.1.1 CAN Transceiver Modes
            1. 7.4.2.1.1.1 CAN Off Mode
            2. 7.4.2.1.1.2 CAN Autonomous: Inactive and Active
            3. 7.4.2.1.1.3 CAN Active
          2. 7.4.2.1.2 Driver and Receiver Function Tables
          3. 7.4.2.1.3 CAN Bus States
  9. Application Information Disclaimer
    1. 8.1 Application Information
      1. 8.1.1 Typical Application
      2. 8.1.2 Design Requirements
        1. 8.1.2.1 Bus Loading, Length and Number of Nodes
      3. 8.1.3 Detailed Design Procedure
        1. 8.1.3.1 CAN Termination
      4. 8.1.4 Application Curves
    2. 8.2 Power Supply Recommendations
    3. 8.3 Layout
      1. 8.3.1 Layout Guidelines
      2. 8.3.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information
    1. 11.1 Tape and Reel Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Power Supply Characteristics

Over recommended operating conditions with TJ = -40°C to 150°C, unless otherwise noted.
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Supply Voltage and Current Characteristics
ISUP_NORMAL Supply current
CAN active
Normal mode, silent mode, and go-to-sleep mode  140 µA
ISUP_STBY  Supply current, Standby mode
CAN autonomous: inactive (2)
60 µA
ISUP_SLEEP Supply current, Sleep mode
CAN autonomous: inactive (2)
20 30 µA
ISUP_BIAS
Additional supply current when in CAN autonomous: active (ISUP(BIAS)
5.5 V < VSUP ≤ 28 V (1)
 
60 µA
UVSUP(R) Undervoltage VSUP threshold rising 3.85 4.4 V
UVSUP(F) Undervoltage VSUP threshold falling 3.5 4.25 V
ICC_NORMAL Supply current
CAN active: dominant
Normal mode
TXD = 0 V, RL = 60 Ω, CL = open
 
60 mA
Normal mode
TXD = 0 V, RL = 50 Ω, CL = open
 
70 mA
VCC supply current normal mode
Dominant with bus fault
Normal mode
TXD = 0 V, RL = open, CL = open, CANH = -25 V
 
110 mA
Supply current
CAN active: recessive
Normal mode
TXD = VIO, RL = 50 Ω, CL = open
 
5 mA
ICC_STBY Supply current, Standby mode
CAN autonomous: inactive
TJ = -40 °C to 85 °C (3)
EN = nSTB = 0 V
 
2 µA
Standby mode
EN = nSTB = 0 V
 
5 µA
ICC_SILENT Supply current, Silent and go-to-sleep mode
 
Silent and go-to-sleep mode
TXD = nSTB = VIO, RL = 50 Ω, CL = open
 
2.9 mA
ICC_SLEEP Supply current, Sleep mode
CAN autonomous: inactive
Sleep mode TJ = -40 °C to 85 °C (3)
EN = 0 V or VIO, nSTB = 0 V
 
2 µA
Sleep mode
EN = 0 V or VIO, nSTB = 0 V
 
5 µA
UVCC(R) Undervoltage VCC threshold rising 4.1 4.4 V
UVCC(F) Undervoltage VCC threshold falling 3.5 3.9 V
VHYS(UVCC) Hysteresis voltage on  UVCC 50 240 320 mV
IIO_NORMAL I/O supply current Normal mode
RXD floating, TXD = 0 V
200 µA
I/O supply current Normal mode, standby mode, or go-to-sleep mode
RXD floating, TXD = VIO
5 µA
IIO_SLEEP I/O supply current Sleep mode TJ = -40 °C to 85 °C (3)
nSTB = 0 V
2.5 µA
I/O supply current Sleep mode
nSTB = 0 V
5 µA
UVIO(R) Under voltage VIO threshold rising Ramp up 1.4 1.65 V
UVIO(F) Under voltage VIO threshold falling Ramp down 1 1.25 V
VHYS(UVIO) Hysteresis voltage on UVIO 30 60 160 mV
ISUP(BIAS) is calculated by subtracting the supply current in CAN autonomous inactive mode from the total supply current in CAN autonomous active mode
After a valid wake-up, the CAN transceiver switches to CAN autonomous active mode and the ISUP(BIAS) current needs to be added to the specified ISUP current in CAN autonomous inactive mode.
Specified by design and verified via bench characterization