JAJST56D October   2001  – February 2024 TFP410

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 T.M.D.S. Pixel Data and Control Signal Encoding
      2. 6.3.2 Universal Graphics Controller Interface Voltage Signal Levels
      3. 6.3.3 Universal Graphics Controller Interface Clock Inputs
    4. 6.4 Device Functional Modes
      1. 6.4.1 Universal Graphics Controller Interface Modes
      2. 6.4.2 Data De-skew Feature
      3. 6.4.3 Hot Plug/Unplug (Auto Connect/Disconnect Detection)
      4. 6.4.4 Device Configuration and I2C RESET Description
      5. 6.4.5 DE Generator
    5. 6.5 Programming
      1. 6.5.1 I2C Interface
    6. 6.6 Register Maps
      1. 6.6.1  VEN_ID Register (Sub-Address = 01−00 ) [reset = 0x014C]
      2. 6.6.2  DEV_ID Register (Sub-Address = 03–02) [reset = 0x0410]
      3. 6.6.3  REV_ID Register (Sub-Address = 04) [reset = 0x00]
      4. 6.6.4  Reserved Register (Sub-Address = 07–05) [reset = 0x641400]
      5. 6.6.5  CTL_1_MODE (Sub-Address = 08) [reset = 0xBE]
      6. 6.6.6  CTL_2_MODE Register (Sub-Address = 09) [reset = 0x00]
      7. 6.6.7  CTL_3_MODE Register (Sub-Address = 0A) [reset = 0x80]
      8. 6.6.8  CFG Register (Sub-Address = 0B)
      9. 6.6.9  RESERVED Register (Sub-Address = 0E–0C) [reset = 0x97D0A9]
      10. 6.6.10 DE_DLY Register (Sub-Address = 32) [reset = 0x00]
      11. 6.6.11 DE_CTL Register (Sub-Address = 33) [reset = 0x00]
      12. 6.6.12 DE_TOP Register (Sub-Address = 34) [reset = 0x00]
      13. 6.6.13 DE_CNT Register (Sub-Address = 37–36) [reset = 0x0000]
      14. 6.6.14 DE_LIN Register (Sub-Address = 39–38) [reset = 0x0000]
      15. 6.6.15 H_RES Register (Sub-Address = 3B−3A)
      16. 6.6.16 V_RES Register (Sub-Address = 3D−3C)
  8. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
        1. 7.2.2.1 Data and Control Signals
        2. 7.2.2.2 Configuration Options
        3. 7.2.2.3 Power Supplies Decoupling
      3. 7.2.3 Application Curves
    3. 7.3 Power Supply Recommendations
      1. 7.3.1 DVDD
      2. 7.3.2 TVDD
      3. 7.3.3 PVDD
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
        1. 7.4.1.1 Layer Stack
        2. 7.4.1.2 Routing High-Speed Differential Signal Traces (RxC-, RxC+, Rx0-, Rx0+, Rx1-, Rx1+, Rx2-, Rx2+)
        3. 7.4.1.3 DVI Connector
      2. 7.4.2 Layout Example
      3. 7.4.3 TI PowerPAD 64-Pin HTQFP Package
  9. Device and Documentation Support
    1. 8.1 ドキュメントの更新通知を受け取る方法
    2. 8.2 サポート・リソース
    3. 8.3 Trademarks
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • PAP|64
サーマルパッド・メカニカル・データ
発注情報

サポート・リソース

テキサス・インスツルメンツ E2E™ サポート・フォーラムは、エンジニアが検証済みの回答と設計に関するヒントをエキスパートから迅速かつ直接得ることができる場所です。既存の回答を検索したり、独自の質問をしたりすることで、設計で必要な支援を迅速に得ることができます。

リンクされているコンテンツは、各寄稿者により「現状のまま」提供されるものです。これらはテキサス・インスツルメンツの仕様を構成するものではなく、必ずしもテキサス・インスツルメンツの見解を反映したものではありません。テキサス・インスツルメンツの使用条件を参照してください。