JAJSMQ2 September 2021 TMAG5170
PRODUCTION DATA
The TMAG5170 offers multiple update rates for system design flexibility. Figure 7-4 shows the different update rates for the TMAG5170 during continuous conversion.
OPERATING MODE | REGISTER SETTING | UPDATE RATE | COMMENT | ||
---|---|---|---|---|---|
SINGLE AXIS | TWO AXIS | THREE AXIS | |||
X, Y, Z Axis | CONV_AVG = 000b | 20 ksps | 13.3 ksps | 10 ksps | Fastest update rate |
X, Y, Z Axis | CONV_AVG = 001b | 13.3 ksps | 8.0 ksps | 5.7 ksps | |
X, Y, Z Axis | CONV_AVG = 010b | 8.0 ksps | 4.4 ksps | 3.1 ksps | |
X, Y, Z Axis | CONV_AVG = 011b | 4.4 ksps | 2.4 ksps | 1.6 ksps | |
X, Y, Z Axis | CONV_AVG = 100b | 2.4 ksps | 1.2 ksps | 0.8 ksps | |
X, Y, Z Axis | CONV_AVG = 101b | 1.2 ksps | 0.6 ksps | 0.4 ksps | Best SNR case |