JAJSPB7A February 2024 – July 2024 TMP110
PRODUCTION DATA
This register is used to configure the operation of the TMP110 and also provides the alert status when ALERT pin is not available on the pin-out.
Return to Register Map.
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
One_Shot | Reserved | Fault[1:0] | Polarity | Alert_Mode | Shutdown | ||
R/W-0b | R-11b | R/W-00b | R/W-0b | R/W-0b | R/W-0b | ||
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Conversion_Rate[1:0] | Alert | Extended_Mode | Reserved | ||||
R/W-10b | R-1b | R/W-0b | R-0000b |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
15 | One_Shot | R/W | 0b | One-shot conversion trigger applicable in shutdown mode only. In continuous conversion mode the bit reads 0b. In shutdown mode the bit reads 1b. Triggering a one-shot conversion happens only when the TMP110 is in shutdown mode. 0b = Active conversion ongoing 1b = Trigger a one-shot conversion or active conversion complete |
14:13 | Reserved | R | 11b | Reserved |
12:11 | Fault[1:0] | R/W | 00b | The fault bit is used to count the number of consecutive conversions for which the alert condition exists before the ALERT pin is asserted or status bit is set. 00b = 1 fault 01b = 2 faults 10b = 4 faults 11b = 6 faults |
10 | Polarity | R/W | 0b | The polarity bit allows the host to adjust the polarity of the ALERT pin/flag output. 0b = ALERT pin/flag output is active low 1b = ALERT pin/flag output is active high |
9 | Alert_Mode | R/W | 0b | The alert mode bit indicates the how the temperature limits operate. 0b = Comparator mode 1b = Alert mode |
8 | Shutdown | R/W | 0b | The shutdown bit is used to change the device conversion mode. 0b = Continuous conversion mode 1b = Shutdown mode |
7:6 | Conversion_Rate[1:0] | R/W | 10b | The conversion rate bits configure the TMP110 conversion period. The default is conversion every 250ms. 00b = 4s / 0.25Hz 01b = 1s / 1Hz 10b = 0.25s / 4Hz 11b = 0.125s / 8Hz |
5 | Alert flag | R | 1b | The alert is a read-only bit which provides the information about the alert status in comparator mode and is not affected by Alert_Mode setting. The polarity bit affects the alert flag. |
4 | Extended_Mode | R/W | 0b | The extended mode bit configures the temperature format. 0b = Normal format with 12-bit 1b = Extended format with 13-bit |
3:0 | Reserved | R | 0000b | Reserved |