JAJSI68 November   2019 TMP392

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     概略回路図
  4. 改訂履歴
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 TMP392 Programming Tables
      2. 7.3.2 Trip Test
      3. 7.3.3 20°C Hysteresis
    4. 7.4 Device Functional Modes
  8. Application and Implementation
    1. 8.1 Applications Information
    2. 8.2 Typical Applications
      1. 8.2.1 Simplified Application Schematic
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
        3. 8.2.1.3 Application Curves
      2. 8.2.2 TMP392 With 10°C Hysteresis
        1. 8.2.2.1 Design Requirements
        2. 8.2.2.2 Detailed Design Procedure
        3. 8.2.2.3 Application Curve
      3. 8.2.3 One Channel Operation for Hot Trip Point up to 124°C
        1. 8.2.3.1 Application Curve
      4. 8.2.4 One Channel Operation for Warm Trip Point from 30°C up to 105°C
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11デバイスおよびドキュメントのサポート
    1. 11.1 ドキュメントの更新通知を受け取る方法
    2. 11.2 サポート・リソース
    3. 11.3 商標
    4. 11.4 静電気放電に関する注意事項
    5. 11.5 Glossary
  12. 12メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

TMP392 Programming Tables

The temperature threshold and hysteresis options for the TMP392 device are programmed using two external 1% E96 standard resistors. The specific resistor value to ground on the SETA input sets the temperature threshold of channel A. The specific resistor value to ground on the SETB input sets the temperature threshold of channel B, as well as the hysteresis for both channel A and channel B.

Table 1. TMP392 Channel A Threshold Setting

CHANNEL A (HOT) TRIP TEMPERATURE (°C) CHANNEL A NOMINAL 1% RESISTORS (KΩ) CHANNEL A (HOT) TRIP RESET TEMPERATURE (°C) FOR HYSTERESIS = 5°C CHANNEL A (HOT) TRIP RESET TEMPERATURE (°C) FOR HYSTERESIS = 10°C
30 1.05 25 20
32 1.21 27 22
34 1.40 29 24
36 1.62 31 26
38 1.87 33 28
40 2.15 35 30
42 2.49 37 32
44 2.87 39 34
46 3.32 41 36
48 3.83 43 38
50 4.42 45 40
52 5.11 47 42
54 5.90 49 44
56 6.81 51 46
58 7.87 53 48
60 9.09 55 50
62 10.5 57 52
64 12.1 59 54
66 14.0 61 56
68 16.2 63 58
70 18.7 65 60
72 21.5 67 62
74 24.9 69 64
76 28.7 71 66
78 33.2 73 68
80 38.3 75 70
82 44.2 77 72
84 51.1 79 74
86 59.0 81 76
88 68.1 83 78
90 78.7 85 80
92 90.9 87 82
94 105 89 84
96 121 91 86
98 140 93 88
100 162 95 90
102 187 97 92
104 215 99 94
106 249 101 96
108 287 103 98
110 332 105 100
112 383 107 102
114 442 109 104
116 511 111 106
118 590 113 108
120 681 115 110
122 787 117 112
124 909 119 114

NOTE

When the SETA pin is grounded or left floating during the device power up, the OUTA pin always stays low. The Channel B functionality is not affected by the SETA channel.

Table 2. TMP392 Channel B Threshold and Hysteresis Setting

CHANNEL B (WARM) TRIP TEMPERATURE (°C) CHANNEL B NOMINAL 1% RESISTORS (KΩ)
CHANNEL B (WARM) TRIP RESET TEMPERATURE (°C)
HYSTERESIS = 5°C HYSTERESIS = 10°C HYSTERESIS = 5°C HYSTERESIS = 10°C
30 90.9 105 25 20
35 78.7 121 30 25
40 68.1 140 35 30
45 59.0 162 40 35
50 51.1 187 45 40
55 44.2 215 50 45
60 38.3 249 55 50
65 33.2 287 60 55
70 28.7 332 65 60
75 24.9 383 70 65
80 21.5 442 75 70
85 18.7 511 80 75
90 16.2 590 85 80
95 14.0 681 90 85
100 12.1 787 95 90
105 10.5 909 100 95

NOTE

When the SETB pin is grounded or left floating during the POR, the OUTB pin always stays low and the Channel A hysteresis is set to 20°C.