8.3.17 Timer Output Selection Register (TOUTPSEL)
The timer output selection is handled within the control register TOUTSEL. The Timer Output Selection Register is shown in Figure 8-16 and described in Table 8-18.
Figure 8-16 Timer Output Selection Register (TOUTPSEL)
Reserved |
TOUTPSEL1 |
TOUTPSEL0 |
R,+000000000000000000000000 |
RW,+00001 |
RW,+00000 |
Legend: R = Read only; RW = Read/Write; -n = value after reset |
Table 8-18 Timer Output Selection Field Description (TOUTPSEL)
BIT |
FIELD |
DESCRIPTION |
31-10 |
Reserved |
Reserved |
9-5 |
TOUTPSEL1 |
Output select for TIMO1
- 0x0: TOUTL0
- 0x1: TOUTH0
- 0x2: TOUTL1
- 0x3: TOUTH1
- 0x4: TOUTL2
- 0x5: TOUTH2
- 0x6: TOUTL3
- 0x7: TOUTH3
- 0x8: TOUTL4
|
- 0x9: TOUTH4
- 0xA: TOUTL5
- 0xB: TOUTH5
- 0xC: TOUTL6
- 0xD: TOUTH6
- 0xE: TOUTL7
- 0xF: TOUTH7
- 0x10 to 0x1F: Reserved
|
4-0 |
TOUTPSEL0 |
Output select for TIMO0
- 0x0: TOUTL0
- 0x1: TOUTH0
- 0x2: TOUTL1
- 0x3: TOUTH1
- 0x4: TOUTL2
- 0x5: TOUTH2
- 0x6: TOUTL3
- 0x7: TOUTH3
- 0x8: TOUTL4
|
- 0x9: TOUTH4
- 0xA: TOUTL5
- 0xB: TOUTH5
- 0xC: TOUTL6
- 0xD: TOUTH6
- 0xE: TOUTL7
- 0xF: TOUTH7
- 0x10 to 0x1F: Reserved
|