SPRS814D March   2012  – October 2019 TMS320C6655 , TMS320C6657

PRODUCTION DATA.  

  1. Device Overview
    1. 1.1 Features
    2. 1.2 Applications
    3. 1.3 Description
    4. 1.4 Functional Block Diagram
  2. Revision History
  3. Device Comparison
    1. 3.1 Device Comparison
  4. Terminal Configuration and Functions
    1. 4.1 Pin Diagram
    2. 4.2 Terminal Functions
  5. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Power Consumption Summary
    5. 5.5 Electrical Characteristics
    6. 5.6 Thermal Resistance Characteristics for [CZH/GZH] Package
    7. 5.7 Timing and Switching Characteristics
      1. 5.7.1  SmartReflex
        1. Table 5-1 SmartReflex 4-Pin VID Interface Switching Characteristics
      2. 5.7.2  Reset Electrical Data / Timing
        1. Table 5-2 Reset Timing Requirements
        2. Table 5-3 Reset Switching Characteristics Over Recommended Operating Conditions
        3. Table 5-4 Boot Configuration Timing Requirements
      3. 5.7.3  Main PLL Stabilization, Lock, and Reset Times
      4. 5.7.4  Main PLL Controller/SRIO/HyperLink/PCIe Clock Input Electrical Data/Timing
        1. Table 5-6 Main PLL Controller/SRIO/HyperLink/PCIe Clock Input Timing Requirements
      5. 5.7.5  DDR3 PLL Input Clock Electrical Data/Timing
        1. Table 5-7 DDR3 PLL DDRSYSCLK1(N|P) Timing Requirements
      6. 5.7.6  External Interrupts Electrical Data/Timing
        1. Table 5-8 NMI and Local Reset Timing Requirements
      7. 5.7.7  DDR3 Memory Controller Electrical Data/Timing
      8. 5.7.8  I2C Electrical Data/Timing
        1. 5.7.8.1 Inter-Integrated Circuits (I2C) Timing
          1. Table 5-9  I2C Timing Requirements
          2. Table 5-10 I2C Switching Characteristics
      9. 5.7.9  SPI Peripheral
        1. 5.7.9.1 SPI Timing
          1. Table 5-11 SPI Timing Requirements
          2. Table 5-12 SPI Switching Characteristics
      10. 5.7.10 HyperLink Electrical Data/Timing
        1. Table 5-13 HyperLink Peripheral Timing Requirements
        2. Table 5-14 HyperLink Peripheral Switching Characteristics
      11. 5.7.11 UART Peripheral
        1. Table 5-15 UART Timing Requirements
        2. Table 5-16 UART Switching Characteristics
      12. 5.7.12 EMIF16 Peripheral
        1. 5.7.12.1 EMIF16 Electrical Data/Timing
          1. Table 5-17 EMIF16 Asynchronous Memory Timing Requirements
      13. 5.7.13 MDIO Timing
        1. Table 5-18 MDIO Timing Requirements
        2. Table 5-19 MDIO Switching Characteristics
      14. 5.7.14 Timers Electrical Data/Timing
        1. Table 5-20 Timer Input Timing Requirements
        2. Table 5-21 Timer Output Switching Characteristics
      15. 5.7.15 General-Purpose Input/Output (GPIO)
        1. 5.7.15.1 GPIO Device-Specific Information
        2. 5.7.15.2 GPIO Electrical Data/Timing
          1. Table 5-22 GPIO Input Timing Requirements
          2. Table 5-23 GPIO Output Switching Characteristics
      16. 5.7.16 McBSP Electrical Data/Timing
        1. 5.7.16.1 McBSP Timing
          1. Table 5-24 McBSP Timing Requirements
          2. Table 5-25 McBSP Switching Characteristics
          3. Table 5-26 McBSP Timing Requirements for FSR When GSYNC = 1
      17. 5.7.17 uPP Timing and Switching
        1. Table 5-27 uPP Timing Requirements
        2. Table 5-28 uPP Switching Characteristics
      18. 5.7.18 Trace Electrical Data/Timing
        1. Table 5-29 DSP Trace Switching Characteristics
        2. Table 5-30 STM Trace Switching Characteristics
      19. 5.7.19 JTAG Electrical Data/Timing
        1. Table 5-31 JTAG Test Port Timing Requirements
        2. Table 5-32 JTAG Test Port Switching Characteristics
  6. Detailed Description
    1. 6.1  Recommended Clock and Control Signal Transition Behavior
    2. 6.2  Power Supplies
      1. 6.2.1 Power Supply to Peripheral I/O Mapping
      2. 6.2.2 Power-Supply Sequencing
        1. 6.2.2.1 Core-Before-IO Power Sequencing
        2. 6.2.2.2 IO-Before-Core Power Sequencing
        3. 6.2.2.3 Prolonged Resets
        4. 6.2.2.4 Clocking During Power Sequencing
      3. 6.2.3 Power-Down Sequence
      4. 6.2.4 Power Supply Decoupling and Bulk Capacitors
    3. 6.3  Power Sleep Controller (PSC)
      1. 6.3.1 Power Domains
      2. 6.3.2 Clock Domains
      3. 6.3.3 PSC Register Memory Map
    4. 6.4  Reset Controller
      1. 6.4.1 Power-on Reset
      2. 6.4.2 Hard Reset
      3. 6.4.3 Soft Reset
      4. 6.4.4 Local Reset
      5. 6.4.5 Reset Priority
      6. 6.4.6 Reset Controller Register
    5. 6.5  Main PLL and PLL Controller
      1. 6.5.1 Main PLL Controller Device-Specific Information
        1. 6.5.1.1 Internal Clocks and Maximum Operating Frequencies
        2. 6.5.1.2 Main PLL Controller Operating Modes
      2. 6.5.2 PLL Controller Memory Map
        1. 6.5.2.1 PLL Secondary Control Register (SECCTL)
          1. Table 6-10 PLL Secondary Control Register (SECCTL) Field Descriptions
        2. 6.5.2.2 PLL Controller Divider Register (PLLDIV2, PLLDIV5, PLLDIV8)
          1. Table 6-11 PLL Controller Divider Register (PLLDIVn) Field Descriptions
        3. 6.5.2.3 PLL Controller Clock Align Control Register (ALNCTL)
          1. Table 6-12 PLL Controller Clock Align Control Register (ALNCTL) Field Descriptions
        4. 6.5.2.4 PLLDIV Divider Ratio Change Status Register (DCHANGE)
          1. Table 6-13 PLLDIV Divider Ratio Change Status Register (DCHANGE) Field Descriptions
        5. 6.5.2.5 SYSCLK Status Register (SYSTAT)
          1. Table 6-14 SYSCLK Status Register (SYSTAT) Field Descriptions
        6. 6.5.2.6 Reset Type Status Register (RSTYPE)
          1. Table 6-15 Reset Type Status Register (RSTYPE) Field Descriptions
        7. 6.5.2.7 Reset Control Register (RSTCTRL)
          1. Table 6-16 Reset Control Register (RSTCTRL) Field Descriptions
        8. 6.5.2.8 Reset Configuration Register (RSTCFG)
          1. Table 6-17 Reset Configuration Register (RSTCFG) Field Descriptions
        9. 6.5.2.9 Reset Isolation Register (RSISO)
          1. Table 6-18 Reset Isolation Register (RSISO) Field Descriptions
      3. 6.5.3 Main PLL Control Register
        1. Table 6-19 Main PLL Control Register 0 (MAINPLLCTL0) Field Descriptions
        2. Table 6-20 Main PLL Control Register 1 (MAINPLLCTL1) Field Descriptions
      4. 6.5.4 Main PLL and PLL Controller Initialization Sequence
    6. 6.6  DDR3 PLL
      1. 6.6.1 DDR3 PLL Control Register
        1. Table 6-21 DDR3 PLL Control Register 0 Field Descriptions
        2. Table 6-22 DDR3 PLL Control Register 1 Field Descriptions
      2. 6.6.2 DDR3 PLL Device-Specific Information
      3. 6.6.3 DDR3 PLL Initialization Sequence
    7. 6.7  Enhanced Direct Memory Access (EDMA3) Controller
      1. 6.7.1 EDMA3 Device-Specific Information
      2. 6.7.2 EDMA3 Channel Controller Configuration
      3. 6.7.3 EDMA3 Transfer Controller Configuration
      4. 6.7.4 EDMA3 Channel Synchronization Events
    8. 6.8  Interrupts
      1. 6.8.1 Interrupt Sources and Interrupt Controller
      2. 6.8.2 CIC Registers
        1. 6.8.2.1 CIC0 Register Map
        2. 6.8.2.2 CIC1 Register Map
        3. 6.8.2.3 CIC2 Register Map
      3. 6.8.3 Interprocessor Register Map
      4. 6.8.4 NMI and LRESET
    9. 6.9  Memory Protection Unit (MPU)
      1. 6.9.1 MPU Registers
        1. 6.9.1.1 MPU Register Map
        2. 6.9.1.2 Device-Specific MPU Registers
          1. 6.9.1.2.1 Configuration Register (CONFIG)
            1. Table 6-44 Configuration Register (CONFIG) Field Descriptions
      2. 6.9.2 MPU Programmable Range Registers
        1. 6.9.2.1 Programmable Range n Start Address Register (PROGn_MPSAR)
          1. Table 6-45 Programmable Range n Start Address Register (PROGn_MPSAR) Field Descriptions
        2. 6.9.2.2 Programmable Range n End Address Register (PROGn_MPEAR)
          1. Table 6-46 Programmable Range n End Address Register (PROGn_MPEAR) Field Descriptions
        3. 6.9.2.3 Programmable Range n Memory Protection Page Attribute Register (PROGn_MPPA)
          1. Table 6-47 Programmable Range n Memory Protection Page Attribute Register (PROGn_MPPA) Field Descriptions
        4. 6.9.2.4 MPU Registers Reset Values
    10. 6.10 DDR3 Memory Controller
      1. 6.10.1 DDR3 Memory Controller Device-Specific Information
    11. 6.11 I2C Peripheral
      1. 6.11.1 I2C Device-Specific Information
      2. 6.11.2 I2C Peripheral Register Description(s)
    12. 6.12 HyperLink Peripheral
      1. 6.12.1 HyperLink Device-Specific Interrupt Event
    13. 6.13 PCIe Peripheral
    14. 6.14 Ethernet Media Access Controller (EMAC)
      1. 6.14.1 EMAC Device-Specific Information
      2. 6.14.2 EMAC Peripheral Register Description(s)
      3. 6.14.3 EMAC Electrical Data/Timing (SGMII)
    15. 6.15 Management Data Input/Output (MDIO)
      1. 6.15.1 MDIO Peripheral Registers
    16. 6.16 Timers
      1. 6.16.1 Timers Device-Specific Information
    17. 6.17 Semaphore2
    18. 6.18 Multichannel Buffered Serial Port (McBSP)
      1. 6.18.1 McBSP Peripheral Register
    19. 6.19 Universal Parallel Port (uPP)
      1. 6.19.1 uPP Register Descriptions
    20. 6.20 Serial RapidIO (SRIO) Port
    21. 6.21 Turbo Decoder Coprocessor (TCP3d)
    22. 6.22 Enhanced Viterbi-Decoder Coprocessor (VCP2)
    23. 6.23 Emulation Features and Capability
      1. 6.23.1 Advanced Event Triggering (AET)
      2. 6.23.2 Trace
      3. 6.23.3 IEEE 1149.1 JTAG
        1. 6.23.3.1 IEEE 1149.1 JTAG Compatibility Statement
    24. 6.24 DSP Core Description
    25. 6.25 Memory Map Summary
    26. 6.26 Boot Sequence
    27. 6.27 Boot Modes Supported and PLL Settings
      1. 6.27.1 Boot Device Field
        1. Table 6-64 Boot Mode Pins: Boot Device Values
      2. 6.27.2 Device Configuration Field
        1. 6.27.2.1 EMIF16 / UART / No Boot Device Configuration
          1. Table 6-65 EMIF16 / UART / No Boot Configuration Field Descriptions
          2. 6.27.2.1.1 No Boot Mode
            1. Table 6-66 No Boot Configuration Field Descriptions
          3. 6.27.2.1.2 UART Boot Mode
            1. Table 6-67 UART Boot Configuration Field Descriptions
          4. 6.27.2.1.3 EMIF16 Boot Mode
            1. Table 6-68 EMIF16 Boot Configuration Field Descriptions
        2. 6.27.2.2 Serial Rapid I/O Boot Device Configuration
          1. Table 6-69 Serial Rapid I/O Configuration Field Descriptions
        3. 6.27.2.3 Ethernet (SGMII) Boot Device Configuration
          1. Table 6-70 Ethernet (SGMII) Configuration Field Descriptions
        4. 6.27.2.4 NAND Boot Device Configuration
          1. Table 6-71 NAND Configuration Field Descriptions
        5. 6.27.2.5 PCI Boot Device Configuration
          1. Table 6-72 PCI Device Configuration Field Descriptions
        6. 6.27.2.6 I2C Boot Device Configuration
          1. 6.27.2.6.1 I2C Master Mode
            1. Table 6-74 I2C Master Mode Device Configuration Field Descriptions
          2. 6.27.2.6.2 I2C Passive Mode
            1. Table 6-75 I2C Passive Mode Device Configuration Field Descriptions
        7. 6.27.2.7 SPI Boot Device Configuration
          1. Table 6-76 SPI Device Configuration Field Descriptions
        8. 6.27.2.8 HyperLink Boot Device Configuration
          1. Table 6-77 HyperLink Boot Device Configuration Field Descriptions
      3. 6.27.3 Boot Parameter Table
        1. Table 6-80 PLL Configuration Field Description
        2. 6.27.3.1   Sleep / XIP Mode Parameter Table
          1. Table 6-82 EMIF16 XIP Option Field Descriptions
        3. 6.27.3.2   SRIO Mode Boot Parameter Table
          1. Table 6-84 SRIO Boot Options Description
        4. 6.27.3.3   Ethernet Mode Boot Parameter Table
          1. Table 6-87 Ethernet Options Field Descriptions
          2. Table 6-88 SGMII Config Field Descriptions
        5. 6.27.3.4   NAND Mode Boot Parameter Table
          1. Table 6-90 NAND Boot Parameter Options Bit Field Descriptions
        6. 6.27.3.5   PCIE Mode Boot Parameter Table
          1. Table 6-92 PCIe Options Field Descriptions
        7. 6.27.3.6   I2C Mode Boot Parameter Table
          1. Table 6-94 Register Description
        8. 6.27.3.7   SPI Mode Boot Parameter Table
          1. Table 6-96 SPI Options Field Description
        9. 6.27.3.8   Hyperlink Mode Boot Parameter Table
          1. Table 6-98 Hyperlink Options Field Descriptions
        10. 6.27.3.9   UART Mode Boot Parameter Table
    28. 6.28 PLL Boot Configuration Settings
    29. 6.29 Second-Level Bootloaders
  7. C66x CorePac
    1. 7.1 Memory Architecture
      1. 7.1.1 L1P Memory
      2. 7.1.2 L1D Memory
      3. 7.1.3 L2 Memory
      4. 7.1.4 MSM SRAM
      5. 7.1.5 L3 Memory
    2. 7.2 Memory Protection
    3. 7.3 Bandwidth Management
    4. 7.4 Power-Down Control
    5. 7.5 C66x CorePac Revision
      1. Table 7-2 CorePac Revision ID Register (MM_REVID) Field Descriptions
    6. 7.6 C66x CorePac Register Descriptions
  8. Device Configuration
    1. 8.1 Device Configuration at Device Reset
    2. 8.2 Peripheral Selection After Device Reset
    3. 8.3 Device State Control Registers
      1. 8.3.1  Device Status Register
        1. Table 8-3 Device Status Register Field Descriptions
      2. 8.3.2  Device Configuration Register
        1. Table 8-4 Device Configuration Register Field Descriptions
      3. 8.3.3  JTAG ID (JTAGID) Register Description
        1. Table 8-5 JTAG ID Register Field Descriptions
      4. 8.3.4  Kicker Mechanism (KICK0 and KICK1) Register
      5. 8.3.5  LRESETNMI PIN Status (LRSTNMIPINSTAT) Register
        1. Table 8-6 LRESETNMI PIN Status Register (LRSTNMIPINSTAT) Field Descriptions
      6. 8.3.6  LRESETNMI PIN Status Clear (LRSTNMIPINSTAT_CLR) Register
        1. Table 8-7 LRESETNMI PIN Status Clear Register (LRSTNMIPINSTAT_CLR) Field Descriptions
      7. 8.3.7  Reset Status (RESET_STAT) Register
        1. Table 8-8 Reset Status Register (RESET_STAT) Field Descriptions
      8. 8.3.8  Reset Status Clear (RESET_STAT_CLR) Register
        1. Table 8-9 Reset Status Clear Register (RESET_STAT_CLR) Field Descriptions
      9. 8.3.9  Boot Complete (BOOTCOMPLETE) Register
        1. Table 8-10 Boot Complete Register (BOOTCOMPLETE) Field Descriptions
      10. 8.3.10 Power State Control (PWRSTATECTL) Register
        1. Table 8-11 Power State Control Register (PWRSTATECTL) Field Descriptions
      11. 8.3.11 NMI Event Generation to CorePac (NMIGRx) Register
        1. Table 8-12 NMI Generation Register (NMIGRx) Field Descriptions
      12. 8.3.12 IPC Generation (IPCGRx) Registers
        1. Table 8-13 IPC Generation Registers (IPCGRx) Field Descriptions
      13. 8.3.13 IPC Acknowledgement (IPCARx) Registers
        1. Table 8-14 IPC Acknowledgement Registers (IPCARx) Field Descriptions
      14. 8.3.14 IPC Generation Host (IPCGRH) Register
        1. Table 8-15 IPC Generation Registers (IPCGRH) Field Descriptions
      15. 8.3.15 IPC Acknowledgement Host (IPCARH) Register
        1. Table 8-16 IPC Acknowledgement Register (IPCARH) Field Descriptions
      16. 8.3.16 Timer Input Selection Register (TINPSEL)
        1. Table 8-17 Timer Input Selection Field Description (TINPSEL)
      17. 8.3.17 Timer Output Selection Register (TOUTPSEL)
        1. Table 8-18 Timer Output Selection Field Description (TOUTPSEL)
      18. 8.3.18 Reset Mux (RSTMUXx) Register
        1. Table 8-19 Reset Mux Register Field Descriptions
      19. 8.3.19 Device Speed (DEVSPEED) Register
        1. Table 8-20 Device Speed Register Field Descriptions
      20. 8.3.20 Pin Control 0 (PIN_CONTROL_0) Register
        1. Table 8-21 Pin Control 0 Register Field Descriptions
      21. 8.3.21 Pin Control 1 (PIN_CONTROL_1) Register
        1. Table 8-22 Pin Control 1 Register Field Descriptions
      22. 8.3.22 uPP Clock Source (UPP_CLOCK) Register
        1. Table 8-23 uPP Clock Source Register Field Descriptions
    4. 8.4 Pullup and Pulldown Resistors
  9. System Interconnect
    1. 9.1 Internal Buses and Switch Fabrics
    2. 9.2 Switch Fabric Connections Matrix
    3. 9.3 TeraNet Switch Fabric Connections
    4. 9.4 Bus Priorities
      1. 9.4.1 Packet DMA Priority Allocation (PKTDMA_PRI_ALLOC) Register
        1. Table 9-3 Packet DMA Priority Allocation Register (PKTDMA_PRI_ALLOC) Field Descriptions
      2. 9.4.2 EMAC / uPP Priority Allocation (EMAC_UPP_PRI_ALLOC) Register
        1. Table 9-4 EMAC / uPP Priority Allocation Register (EMAC_UPP_PRI_ALLOC) Field Descriptions
  10. 10Device and Documentation Support
    1. 10.1 Device Nomenclature
    2. 10.2 Tools and Software
    3. 10.3 Documentation Support
    4. 10.4 Related Links
    5. 10.5 Support Resources
    6. 10.6 Trademarks
    7. 10.7 Electrostatic Discharge Caution
    8. 10.8 Glossary
  11. 11Mechanical Packaging and Orderable Information
    1. 11.1 Packaging Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • CZH|625
  • GZH|625
サーマルパッド・メカニカル・データ
発注情報

Device State Control Registers

The C665x device has a set of registers that are used to provide the status or configure certain parts of its peripherals. Table 8-2 lists these registers.

Table 8-2 Device State Control Registers

ADDRESS START ADDRESS END SIZE FIELD DESCRIPTION
0x02620000 0x02620007 8B Reserved
0x02620008 0x02620017 16B Reserved
0x02620018 0x0262001B 4B JTAGID See Section 8.3.3.
0x0262001C 0x0262001F 4B Reserved
0x02620020 0x02620023 4B DEVSTAT See Section 8.3.1.
0x02620024 0x02620037 20B Reserved
0x02620038 0x0262003B 4B KICK0 See Section 8.3.4.
0x0262003C 0x0262003F 4B KICK1
0x02620040 0x02620043 4B DSP_BOOT_ADDR0 The boot address for C66x DSP CorePac0
0x02620044 0x02620047 4B DSP_BOOT_ADDR1 The boot address for C66x DSP CorePac1 (C6657) or Reserved (C6655)
0x02620048 0x0262004B 4B Reserved
0x0262004C 0x0262004F 4B Reserved
0x02620050 0x02620053 4B Reserved
0x02620054 0x02620057 4B Reserved
0x02620058 0x0262005B 4B Reserved
0x0262005C 0x0262005F 4B Reserved
0x02620060 0x026200DF 128B Reserved
0x026200E0 0x0262010F 48B Reserved
0x02620110 0x02620117 8B MACID See Section 6.14.
0x02620118 0x0262012F 24B Reserved
0x02620130 0x02620133 4B LRSTNMIPINSTAT_CLR See Section 8.3.6.
0x02620134 0x02620137 4B RESET_STAT_CLR See Section 8.3.8.
0x02620138 0x0262013B 4B Reserved
0x0262013C 0x0262013F 4B BOOTCOMPLETE See Section 8.3.9.
0x02620140 0x02620143 4B Reserved
0x02620144 0x02620147 4B RESET_STAT See Section 8.3.7.
0x02620148 0x0262014B 4B LRSTNMIPINSTAT See Section 8.3.5.
0x0262014C 0x0262014F 4B DEVCFG See Section 8.3.2.
0x02620150 0x02620153 4B PWRSTATECTL See Section 8.3.10.
0x02620154 0x02620157 4B SRIO_SERDES_STS See Section 10.3.
0x02620158 0x0262015B 4B SGMII_SERDES_STS See Section 10.3.
0x0262015C 0x0262015F 4B PCIE_SERDES_STS
0x02620160 0x02620163 4B HYPERLINK_SERDES_STS See Section 10.3.
0x02620164 0x02620167 4B Reserved
0x02620168 0x0262016B 4B Reserved
0x0262016C 0x0262016F 4B UPP_CLOCK See Section 8.3.22.
0x02620170 0x02620183 20B Reserved
0x02620184 0x0262018F 12B Reserved
0x02620190 0x02620193 4B Reserved
0x02620194 0x02620197 4B Reserved
0x02620198 0x0262019B 4B Reserved
0x0262019C 0x0262019F 4B Reserved
0x026201A0 0x026201A3 4B Reserved
0x026201A4 0x026201A7 4B Reserved
0x026201A8 0x026201AB 4B Reserved
0x026201AC 0x026201AF 4B Reserved
0x026201B0 0x026201B3 4B Reserved
0x026201B4 0x026201B7 4B Reserved
0x026201B8 0x026201BB 4B Reserved
0x026201BC 0x026201BF 4B Reserved
0x026201C0 0x026201C3 4B Reserved
0x026201C4 0x026201C7 4B Reserved
0x026201C8 0x026201CB 4B Reserved
0x026201CC 0x026201CF 4B Reserved
0x026201D0 0x026201FF 48B Reserved
0x02620200 0x02620203 4B NMIGR0 See Section 8.3.11.
0x02620204 0x02620207 4B NMIGR1 See Section 8.3.11.(C6657) or Reserved (C6655))
0x02620208 0x0262020B 4B Reserved
0x0262020C 0x0262020F 4B Reserved
0x02620210 0x02620213 4B Reserved
0x02620214 0x02620217 4B Reserved
0x02620218 0x0262021B 4B Reserved
0x0262021C 0x0262021F 4B Reserved
0x02620220 0x0262023F 32B Reserved
0x02620240 0x02620243 4B IPCGR0 See Section 8.3.12.
0x02620244 0x02620247 4B IPCGR1 See Section 8.3.12. (C6657) or Reserved (C6655))
0x02620248 0x0262024B 4B Reserved
0x0262024C 0x0262024F 4B Reserved
0x02620250 0x02620253 4B Reserved
0x02620254 0x02620257 4B Reserved
0x02620258 0x0262025B 4B Reserved
0x0262025C 0x0262025F 4B Reserved
0x02620260 0x0262027B 28B Reserved
0x0262027C 0x0262027F 4B IPCGRH See Section 8.3.14.
0x02620280 0x02620283 4B IPCAR0 See Section 8.3.13.
0x02620284 0x02620287 4B IPCAR1 See Section 8.3.13. (C6657) or Reserved (C6655))
0x02620288 0x0262028B 4B Reserved
0x0262028C 0x0262028F 4B Reserved
0x02620290 0x02620293 4B Reserved
0x02620294 0x02620297 4B Reserved
0x02620298 0x0262029B 4B Reserved
0x0262029C 0x0262029F 4B Reserved
0x026202A0 0x026202BB 28B Reserved
0x026202BC 0x026202BF 4B IPCARH See Section 8.3.15.
0x026202C0 0x026202FF 64B Reserved
0x02620300 0x02620303 4B TINPSEL See Section 8.3.16.

See Section 8.3.17.

0x02620304 0x02620307 4B TOUTPSEL
0x02620308 0x0262030B 4B RSTMUX0 See Section 8.3.18.
0x0262030C 0x0262030F 4B RSTMUX1 See Section 8.3.18. (C6657) or Reserved (C6655))
0x02620310 0x02620313 4B Reserved
0x02620314 0x02620317 4B Reserved
0x02620318 0x0262031B 4B Reserved
0x0262031C 0x0262031F 4B Reserved
0x02620320 0x02620323 4B Reserved
0x02620324 0x02620327 4B Reserved
0x02620328 0x0262032B 4B MAINPLLCTL0 See Section 6.5.
0x0262032C 0x0262032F 4B MAINPLLCTL1
0x02620330 0x02620333 4B DDR3PLLCTL0 See Section 6.6.
0x02620334 0x02620337 4B DDR3PLLCTL1
0x02620338 0x0262033B 4B Reserved
0x0262033C 0x0262033F 4B Reserved
0x02620340 0x02620343 4B SGMII_SERDES_CFGPLL See Section 10.3.
0x02620344 0x02620347 4B SGMII_SERDES_CFGRX0
0x02620348 0x0262034B 4B SGMII_SERDES_CFGTX0
0x0262034C 0x0262034F 4B Reserved
0x02620350 0x02620353 4B Reserved
0x02620354 0x02620357 4B Reserved
0x02620358 0x0262035B 4B PCIE_SERDES_CFGPLL
0x0262035C 0x0262035F 4B Reserved
0x02620360 0x02620363 4B SRIO_SERDES_CFGPLL See Section 10.3.
0x02620364 0x02620367 4B SRIO_SERDES_CFGRX0
0x02620368 0x0262036B 4B SRIO_SERDES_CFGTX0
0x0262036C 0x0262036F 4B SRIO_SERDES_CFGRX1
0x02620370 0x02620373 4B SRIO_SERDES_CFGTX1
0x02620374 0x02620377 4B SRIO_SERDES_CFGRX2
0x02620378 0x0262037B 4B SRIO_SERDES_CFGTX2
0x0262037C 0x0262037F 4B SRIO_SERDES_CFGRX3
0x02620380 0x02620383 4B SRIO_SERDES_CFGTX3
0x02620384 0x02620387 8B Reserved
0x02620388 0x026203AF 28B Reserved
0x026203B0 0x026203B3 4B Reserved
0x026203B4 0x026203B7 4B HYPERLINK_SERDES_CFGPLL See Section 10.3.
0x026203B8 0x026203BB 4B HYPERLINK_SERDES_CFGRX0
0x026203BC 0x026203BF 4B HYPERLINK_SERDES_CFGTX0
0x026203C0 0x026203C3 4B HYPERLINK_SERDES_CFGRX1
0x026203C4 0x026203C7 4B HYPERLINK_SERDES_CFGTX1
0x026203C8 0x026203CB 4B HYPERLINK_SERDES_CFGRX2
0x026203CC 0x026203CF 4B HYPERLINK_SERDES_CFGTX2
0x026203D0 0x026203D3 4B HYPERLINK_SERDES_CFGRX3
0x026203D4 0x026203D7 4B HYPERLINK_SERDES_CFGTX3
0x026203D8 0x026203DB 4B Reserved
0x026203DC 0x026203F7 28B Reserved
0x026203F8 0x026203FB 4B DEVSPEED See Section 8.3.19.
0x026203FC 0x026203FF 4B Reserved
0x02620400 0x02620403 4B CHIP_MISC_CTL See Section 9.4.
0x02620404 0x02620467 100B Reserved
0x02620468 0x0262057f 280B Reserved
0x02620580 0x02620583 4B PIN_CONTROL_0 See Section 8.3.20.
0x02620584 0x02620587 4B PIN_CONTROL_1 See Section 8.3.21.
0x02620588 0x0262058B 4B EMAC_UPP_PRI_ALLOC See Section 9.4.