JAJSG89A January 2015 – September 2018 TPL5010
PRODUCTION DATA.
During normal operating mode, the TPL5010 asserts periodic WAKE pulses in response to valid DONE pulses from the µC. If either a manual reset is applied (logic HIGH on DELAY/M_RST pin), or the µC does not issue a DONE pulse within the required time, the TPL5010 asserts the RSTn signal to the µC and restarts its internal counters. See Figure 8 and Figure 10 .