JAJSOQ1 October   2023 TPS1210-Q1

ADVANCE INFORMATION  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
  9. Parameter Measurement Information
  10. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Charge Pump and Gate Driver Output (VS, G1PU, G1PD, G2, BST, SRC)
      2. 9.3.2 Capacitive Load Driving Using FET Gate (G1PU, G1PD) Slew Rate Control
      3. 9.3.3 Short-Circuit Protection
        1. 9.3.3.1 Short-Circuit Protection With Auto-Retry
        2. 9.3.3.2 Short-Circuit Protection With Latch-Off
      4. 9.3.4 Undervoltage Protection (UVLO)
      5. 9.3.5 Reverse Polarity Protection
      6. 9.3.6 Short-Circuit Protection Diagnosis (SCP_TEST)
      7. 9.3.7 TPS1210x-Q1 as a Simple Gate Driver
    4. 9.4 Device Functional Modes
  11. 10Application and Implementation
    1. 10.1 Application Information
      1. 10.1.1 Application Limitations
        1. 10.1.1.1 Short-Circuit Protection Delay
        2. 10.1.1.2 Short-Circuit Protection Threshold
    2. 10.2 Typical Application: Circuit Breaker in Battery Management System (BMS) using Low Side Current Sense
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
    3. 10.3 Power Supply Recommendations
    4. 10.4 Layout
      1. 10.4.1 Layout Guidelines
      2. 10.4.2 Layout Example
  12. 11Device and Documentation Support
    1. 11.1 ドキュメントの更新通知を受け取る方法
    2. 11.2 サポート・リソース
    3. 11.3 Trademarks
    4. 11.4 静電気放電に関する注意事項
    5. 11.5 用語集
  13. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Tape and Reel Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Reverse Polarity Protection

The TPS1210x-Q1 devices features integrated reverse polarity protection to protect the device from failing during input and output reverse polarity faults. Reverse polarity faults occur during installation and maintenance of the end equipments. The device is tolerant to reverse polarity voltages down to –45 V both on input and on the output.

On the output side, the device can see transient negative voltages during regular operation due to output cable harness inductance kickbacks when the switches are turned OFF. In such systems the output negative voltage level is limited by the output side TVS or a diode.