JAJSM93B june   2022  – may 2023 TPS1641

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Device Comparison Table
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Timing Requirements
    7. 7.7 Typical Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1  Enable and Shutdown Input (EN/SHDN)
      2. 8.3.2  Overvoltage Protection (OVP)
      3. 8.3.3  Output Slew Rate and Inrush Current Control (dVdt)
      4. 8.3.4  Active Current Limiting (ILIM) With the TPS16412, TPS16413, TPS16416, and TPS16417
      5. 8.3.5  Active Power Limiting (PLIM) With the TPS16410, TPS16411, TPS16414, and TPS16415
        1. 8.3.5.1 Internal Current Limit for the TPS16410 and TPS16411
      6. 8.3.6  Overcurrent Protection (IOCP) and Blanking Time (IDLY or PDLY) for Transient Loads
      7. 8.3.7  Fast-Trip and Short-Circuit Protection
      8. 8.3.8  Analog Load Current Monitor (IMON) on the IOCP Pin
      9. 8.3.9  IN to OUT Short Detection (TPS16410, TPS16411, TPS16412, and TPS16413)
      10. 8.3.10 Thermal Shutdown and Overtemperature Protection
      11. 8.3.11 Fault Response and Indication (FLT)
    4. 8.4 Device Functional Modes
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application: 15-W Power Limiting for Low Power Circuits (LPCs)
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Setting Overvoltage Setpoints
        2. 9.2.2.2 Setting the Output Overcurrent Setpoint (IOCP)
        3. 9.2.2.3 Setting the Output Power Limit
        4. 9.2.2.4 Monitoring the Output Current
        5. 9.2.2.5 Limiting the Inrush Current and Setting the Output Slew Rate
      3. 9.2.3 Application Curves
    3. 9.3 System Examples
      1. 9.3.1 Accurate Power or Current Limiting at the Output of DC/DC or Flyback Converter
    4. 9.4 Best Design Practices
    5. 9.5 Power Supply Recommendations
      1. 9.5.1 Transient Protection
    6. 9.6 Layout
      1. 9.6.1 Layout Guidelines
      2. 9.6.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 ドキュメントの更新通知を受け取る方法
    2. 10.2 サポート・リソース
    3. 10.3 Trademarks
    4. 10.4 静電気放電に関する注意事項
    5. 10.5 用語集
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

特長

  • 動作電圧範囲 (IN):
    • 4.5V~40V (電力制限デバイス)
    • 2.7V~40V (電流制限デバイス)
  • 出力側で最大 -1V の負電圧に対応
  • 非常に小さいオン抵抗RON = 152mΩ (標準値)
  • 2W~64W の電力制限
  • 0.03A~1.8A の電流制限
  • 入力と出力の間の短絡を検出し、FLT ピンで通知
  • FLT 出力を診断と外部 PFET の駆動に使用可能
  • 15W 時に ±5% の精度の電力制限 (電力制限デバイス)
  • 1A 時に ±6% の精度の電流制限 (電流制限デバイス)
  • 構成可能な過電圧保護
  • 構成可能な過電流保護 (IOCP)
  • 過渡電流のブランキング時間を構成可能
  • 外部 FET による最大 60V の過電圧保護
  • 突入電流からの保護のために出力スルーレート制御 (dVdt) を調整可能
  • イネーブルおよびシャットダウン制御
  • IOCP ピンで出力負荷電流を監視
  • サーマル・シャットダウンによる過熱保護 (OTP)
  • 小型サイズ:QFN 3mm × 3 mm (0.5mm ピッチ)