JAJSHM7B June 2019 – November 2021 TPS1HB50-Q1
PRODUCTION DATA
When switching off an inductive load, the inductor can impose a negative voltage on the output of the switch. The TPS1HB50-Q1 includes a voltage clamp to limit voltage across the FET. The maximum acceptable load inductance is a function of the device robustness.
For more information on driving inductive loads, refer to TI's How To Drive Inductive, Capacitive, and Lighting Loads With Smart High Side Switches application report.