JAJSN87A July 2022 – December 2022 TPS1HC30-Q1
PRODUCTION DATA
This device possesses thermal shutdown (TABS) circuitry as a protection from overheating. For continuous normal operation, the junction temperature must not exceed the thermal-shutdown trip point. If the junction temperature exceeds the thermal-shutdown trip point, the output turns off. When the junction temperature falls below the thermal-shutdown trip point, the output turns on again.
Use the following equation to calculate the power dissipated by the device.
where
After determining the power dissipated by the device, calculate the junction temperature from the ambient temperature and the device thermal impedance.
For more information, please see the How to Drive Resistive, Inductive, Capacitive, and Lighting Loads application note.