SLUSC25A February 2015 – August 2017 TPS2388
PRODUCTION DATA.
COMMAND = 0Fh with 1 Data Byte, Read Only
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
– | CLASS P4 | DETECT P4 | |||||
R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | R-0 | R-0 |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit Descriptions: These bits represent the most recent classification and detection results for port n. These bits are cleared when port n is turned off.
Bit | Field | Type | Reset | Description | ||||||
---|---|---|---|---|---|---|---|---|---|---|
7 | – | R | 0 | Reserved | ||||||
6–4 | CLASS Pn | R | 0 | Most recent classification result on port n. The selection is as following: |
||||||
CLASS Pn | Class Status | |||||||||
0 | 0 | 0 | Unknown | |||||||
0 | 0 | 1 | Class 1 | |||||||
0 | 1 | 0 | Class 2 | |||||||
0 | 1 | 1 | Class 3 | |||||||
1 | 0 | 0 | Class 4 | |||||||
1 | 0 | 1 | Reserved – read as Class 0 | |||||||
1 | 1 | 0 | Class 0 | |||||||
1 | 1 | 1 | Overcurrent | |||||||
3–0 | DETECT Pn | R | 0 | Most recent detection result on port n. The selection is as following: |
||||||
DETECT Pn | Class Status | |||||||||
0 | 0 | 0 | 0 | Unknown | ||||||
0 | 0 | 0 | 1 | Short-circuit | ||||||
0 | 0 | 1 | 0 | Reserved | ||||||
0 | 0 | 1 | 1 | Too Low | ||||||
0 | 1 | 0 | 0 | Valid | ||||||
0 | 1 | 0 | 1 | Too High | ||||||
0 | 1 | 1 | 0 | Open Circuit | ||||||
0 | 1 | 1 | 1 | Reserved | ||||||
1 | 1 | 1 | 0 | MOSFET fault | ||||||