JAJSMF5B september 2022 – june 2023 TPS25990
PRODUCTION DATA
The TPS25990 implements undervoltage lockout on VDD and VIN in case the applied voltage becomes too low for the system or device to properly operate. The undervoltage lockout has a default internal threshold (VUVP) on VDD and programmable threshold (VUVLOIN) on VIN. Alternatively, the UVLO comparator on the EN/UVLO pin allows the undervoltage protection threshold to be externally adjusted to a user defined value. Figure 8-21 and Equation 1 show how a resistor divider can be used to set the UVLO set point for a given voltage supply.
The VIN UVLO fault threshold can also be programmed using PMBus® writes to VIN_UV_FLT register.
The EN/UVLO pin implements a bi-level threshold and can be used to control the device from an external host.