JAJSJV7C december 2020 – may 2023 TPS272C45
PRODUCTION DATA
To set the current limit thresholds, connect resistors from both ILIM1 and ILIM2 pins to GND. The current limit threshold for each channel is determined by Equation 1 (RILIMx in kΩ):
The nominal KCL value to be used in the calculation is 20.5 A.kΩ. The allowed RILIMx range is between 5 kΩ and 28.2 kΩ. If either pin is floating, grounded, or outside of the range specified, the current limit defaults to an internal level that is defined in the Specifications section of this document.