JAJSRQ0A October 2023 – February 2024 TPS274C65CP
PRODUCTION DATA
The following faults are a register a fault that show on the ST pin:
Condition |
VS |
VDD |
ENx |
OUTx |
DIAG_EN |
LATCH |
VS_FAULT |
STx |
FAULT Recovery |
---|---|---|---|---|---|---|---|---|---|
VS Undervoltage |
< VS_UVP |
> VDD,UVLO |
X |
X |
X |
X |
L |
H |
- |
Normal |
> VS_UVP | > VDD,UVLO |
L |
L |
X |
X |
H |
H |
- |
> VS_UVP | > VDD,UVLO |
H |
H |
X |
X |
H |
H |
- |
|
OFF-state Short to Supply, OFF-state open load |
> VS_UVP | > VDD,UVLO |
L |
H |
H |
X |
H |
L |
- |
Short to GND, Overload, TSD | > VS_UVP | > VDD,UVLO |
H |
L |
X |
L |
H |
L |
Auto-retry |
> VS_UVP | > VDD,UVLO | H | L | X | H | H | L |
Latch-off. Fault recovers when ENx toggles. |