JAJSK37E october 2020 – august 2023 TPS37
PRODUCTION DATA
This design requires voltage supervision on an AC, with a known operating frequency, power supply rail. The overvoltage fault sensing is achieved by monitoring the DC output of a full bridge rectifier while the undervoltage fault is detected by inputting a half wave signal and its voltage frequency and magnitude are being monitored. The target output of this TPS37A application is for 5 V reset logic.
PARAMETER | DESIGN REQUIREMENT | DESIGN RESULT |
---|---|---|
Power Rail Voltage Supervision | Monitor 24 VAC 800 Hz power supply for undervoltage and overvoltage conditions. Trigger undervoltage fault at 5 V and overvoltage fault at 24 V. | TPS37A provides voltage monitoring with 1.5% max accuracy with adjustable/non-adjustable variations. |
Maximum Input Voltage | Operate with power supply input up to 34 V. | The TPS37A can support a VDD of up to 65 V. |
Output logic voltage | Open-Drain Output Topology | An open-drain output is recommended to provide the a 5 V reset signal. |
SENSE Delay when a fault is detected | RESET delay of at least 0.625 ms which is the time between half wave cycles | CCTS2 = 5.6 nF sets 717 µs delay |
Voltage Monitor Accuracy | Maximum voltage monitor accuracy of 1.5%. | The TPS37A has 1.5% maximum voltage monitor accuracy. |