JAJSP58 September 2022 TPS544C26
ADVANCE INFORMATION
CMD Address | 40h |
Write Transaction: | Write Byte |
Read Transaction: | Read Byte |
Format: | Unsigned Binary (1 byte) |
NVM Backup: | EEPROM |
Updates: | On-the-fly |
The VOUT_OV_FAULT_LIMIT command sets the value of the output voltage sensed at the (VOSNS − GOSNS) pins that causes an output overvoltage fault. SEL_OVF bits set an overvoltage fault threshold relative to the current VOUT setting that is commanded by either SVID SetVID command or I2C (A6h) VOUT_CMD. The VOUT Tracking OVF function is activated after the soft-start ramp completes.
Following an overvoltage fault condition, the device responds according to (41h) VOUT_OV_FAULT_RESP. Due to the lack of an I2C alert pin, the TPS544C26 device does not have a way to notify the host.
Return to Supported I2C and Default Values.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
R | R | R | R | R | R | R/W | R/W |
Reserved | SEL_OVF |
LEGEND: R/W = Read/Write; R = Read only |
Bit | Field | Access | Reset | Description |
---|---|---|---|---|
7:2 | Reserved | R | 000000b | Not used and always set to 0. |
1:0 | SEL_OVF | R/W | NVM | Sets the overvoltage fault
threshold. 00b: VOUT Tracking OVF threshold = +100 mV 01b: VOUT Tracking OVF threshold = +150 mV 10b: VOUT Tracking OVF threshold = +200 mV 11b: VOUT Tracking OVF threshold = +300 mV |