SLVSFM1A March 2021 – November 2023 TPS62902
PRODUCTION DATA
The TPS62902 has two operating modes: forced PWM mode discussed in this section and PWM/PFM as discussed in Section 7.4.3.
With the MODE/S-CONF pin configured for PWM mode, the TPS62902 operates with pulse width modulation in continuous conduction mode (CCM) with a nominal switching frequency of 2.5/1.0 MHz. The frequency variation in PWM is controlled and depends on VIN, VOUT, and the inductance. The on-time in forced PWM mode is given by Equation 3: