JAJST54F July   2007  – February 2024 TRS202E

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Electrical Characteristics
    6. 5.6  Electrical Characteristics: Driver
    7. 5.7  Electrical Characteristics: Receiver
    8. 5.8  Switching Characteristics: Driver
    9. 5.9  Switching Characteristics: Receiver
    10. 5.10 Typical Characteristics
  7.   Parameter Measurement Information
  8. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Power
      2. 6.3.2 RS-232 Driver
      3. 6.3.3 RS-232 Receiver
    4. 6.4 Device Functional Modes
      1. 6.4.1 VCC Powered by 5V
      2. 6.4.2 VCC Unpowered
      3. 6.4.3 Truth Tables
  9. Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Application
      1. 7.2.1 Design Requirements
      2. 7.2.2 Detailed Design Procedure
        1. 7.2.2.1 Capacitor Selection
      3. 7.2.3 Application Curves
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  10. Device and Documentation Support
    1. 8.1 ドキュメントの更新通知を受け取る方法
    2. 8.2 サポート・リソース
    3. 8.3 Trademarks
    4. 8.4 静電気放電に関する注意事項
    5. 8.5 用語集
  11. Revision History
  12. 10Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

ESD Ratings

VALUEUNIT
V(ESD)Electrostatic dischargeHuman-body model (HBM),
per ANSI/ESDA/JEDEC JS-001(1)
Pins 7, 8, 13, 14, 15±15000V
All other pins±2000
Charged-device model (CDM),
per JEDEC specification JESD22-C101(2)
All pins±1500
IEC 61000-4-2 contact dischargePins 7, 8, 13, 14, 15±8000
IEC 61000-4-2 air-gap dischargePins 7, 8, 13, 14, 15±15000
JEDEC document JEP155 states that 500V HBM allows safe manufacturing with a standard ESD control process.