SLLS807A June   2007  – July 2024 TRS213

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  Recommended Operating Conditions
    3. 5.3  Thermal Information
    4. 5.4  Electrical Characteristics
    5. 5.5  Electrical Characteristics, Driver
    6. 5.6  Switching Characteristics, Driver
    7. 5.7  ESD Protection, Driver
    8. 5.8  Electrical Characteristics, Receiver
    9. 5.9  Switching Characteristics, Receiver
    10. 5.10 ESD Protection, Receiver
  7. Parameter Measurement Information
  8. Functional Modes
  9. Application and Implementation
    1. 8.1 Typical Application
  10. Device and Documentation Support
    1. 9.1 Receiving Notification of Documentation Updates
    2. 9.2 Support Resources
    3. 9.3 Trademarks
    4. 9.4 Electrostatic Discharge Caution
    5. 9.5 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ

Switching Characteristics, Receiver

over operating free-air temperature range (unless otherwise noted) (1)
PARAMETERTEST CONDITIONSMINTYP(2)MAXUNIT
tPLH(R)Propagation delay time,
low- to high-level output
CL = 150pF,See Figure 6-4SHDN = VCC0.510μs
SHDN = 0V, R4–R5440
tPHL(R)Propagation delay time,
high- to low-level output
CL = 150pF,See Figure 6-40.510μs
tenOutput enable timeCL = 150pF,See Figure 6-5600ns
tdisOutput disable timeCL = 150pF,See Figure 6-5200ns
Test conditions are C1–C4 = 0.1μF at VCC = 5V ± 0.5V.
All typical values are at VCC = 5V, and TA = 25°C.