JAJSI96D February   2019  – December 2023 TUSB216

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Timing Requirements
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 High-Speed Boost
      2. 7.3.2 RX Sensitivity
    4. 7.4 Device Functional Modes
      1. 7.4.1 Low-Speed (LS) Mode
      2. 7.4.2 Full-Speed (FS) Mode
      3. 7.4.3 High-Speed (HS) Mode
      4. 7.4.4 High-Speed Downstream Port Electrical Compliance Test Mode
      5. 7.4.5 Shutdown Mode
      6. 7.4.6 I2C Mode
      7. 7.4.7 BC 1.2 Battery Charging Controller
    5. 7.5 TUSB216 Registers
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Test Procedure to Construct USB High-speed Eye Diagram
          1. 8.2.2.1.1 For a Host Side Application
          2. 8.2.2.1.2 For a Device Side Application
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 ドキュメントの更新通知を受け取る方法
    2. 9.2 サポート・リソース
    3. 9.3 Trademarks
    4. 9.4 静電気放電に関する注意事項
    5. 9.5 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

デバイスごとのパッケージ図は、PDF版データシートをご参照ください。

メカニカル・データ(パッケージ|ピン)
  • RWB|12
サーマルパッド・メカニカル・データ
発注情報

Application Curves

GUID-42935026-67B0-4014-9589-6916499958B4-low.gifFigure 8-2 Near End Eye Measurement Set-Up With Pre-Channel Cable
GUID-7DA339C2-3B13-4B3D-A75B-4017C595C54B-low.png
Figure 8-3 2 Meter Pre-Channel Without TUSB216
GUID-D90F1B9E-62EA-4713-8C6F-1E20506DA087-low.png
Figure 8-5 2 Meter Pre-Channel With TUSB216 BOOST=0 RX_SEN=HIGH
GUID-3AE8CED3-E77C-4160-892A-749E4B186095-low.png
Figure 8-7 3 Meter Pre-Channel With TUSB216 BOOST=0 RX_SEN=HIGH
GUID-74B3BE6F-1711-4754-9A37-9B4052BF6A43-low.png
Figure 8-9 5 Meter Pre-Channel With TUSB216 BOOST=1 RX_SEN=MED
GUID-73A2302D-1858-4439-BE01-03CBAF5E3929-low.png
Figure 8-4 2 Meter Pre-Channel With TUSB216 BOOST=1 RX_SEN=MED
GUID-79E54E19-7264-4ACA-B6F6-1A9E6462E0ED-low.png
Figure 8-6 3 Meter Pre-Channel Without TUSB216
GUID-BD935293-877D-4A41-B3FC-D482FA3B3D87-low.png
Figure 8-8 5 Meter Without TUSB216
GUID-DC71C13C-CAC2-452D-AEF6-AE6EB5DF9EB6-low.png
Figure 8-10 5 Meter Pre-Channel With TUSB216 BOOST=2 RX_SEN=MED
GUID-AA704C29-B2D9-4CA2-95CD-9E06AFA0A0B0-low.gifFigure 8-11 Near End Eye Measurement Set-Up With Post-Channel Cable
GUID-7BE9095A-DD78-4618-A256-1D5528FB59AA-low.png
Figure 8-12 6 Inches Post Channel Without TUSB216
GUID-528BE490-5927-45B5-9F4C-E70458AD23E7-low.png
Figure 8-14 1 Meter Post-Channel Without TUSB216
GUID-EC16E0C8-E953-4D00-A410-056C2DAF6182-low.png
Figure 8-16 1 Meter Post-Channel With TUSB216 BOOST=0 RX_SEN=HIGH
GUID-91EAD0E6-3509-4465-95DC-55FA9C3CD941-low.png
Figure 8-18 2 Meter Post-Channel With TUSB216 BOOST=1 RX_SEN=MED
GUID-B026D8E3-209B-4886-9A44-72A505156B90-low.png
Figure 8-20 4 Meter Post-Channel Without TUSB216
GUID-BC7758AE-0C90-4CB3-9826-BC9A75226D65-low.png
Figure 8-13 6 Inches Post-Channel With TUSB216 BOOST=0 RX_SEN=HIGH
GUID-8A5B9148-9355-43E0-BCAC-4B81E419304D-low.png
Figure 8-15 1 Meter Post-Channel With TUSB216 BOOST=0 RX_SEN=MED
GUID-1F833079-B710-49B7-B422-DB20284EF02B-low.png
Figure 8-17 2 Meter Post-Channel Without TUSB216
GUID-85709962-460C-4505-BD91-CB59B9467F72-low.png
Figure 8-19 2 Meter Post-Channel With TUSB216 BOOST=1 RX_SEN=HIGH
GUID-B207137E-6A3C-4A5D-B9DE-64AFAF441484-low.png
Figure 8-21 4 Meter Post-Channel With TUSB216 BOOST=2 RX_SEN=MED