JAJSK22 June   2021 TUSB217A

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Timing Requirements
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 High-Speed Boost
      2. 8.3.2 RX Sensitivity
    4. 8.4 Device Functional Modes
      1. 8.4.1 Low-Speed (LS) Mode
      2. 8.4.2 Full-Speed (FS) Mode
      3. 8.4.3 High-Speed (HS) Mode
      4. 8.4.4 High-Speed Downstream Port Electrical Compliance Test Mode
      5. 8.4.5 Shutdown Mode
      6. 8.4.6 I2C Mode
      7. 8.4.7 BC 1.2 Battery Charging Controller
    5. 8.5 TUSB217A Registers
  9. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Test Procedure to Construct USB High-speed Eye Diagram
          1. 9.2.2.1.1 For a Host Side Application
          2. 9.2.2.1.2 For a Device Side Application
      3. 9.2.3 Application Curves
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Example
  12. 12Device and Documentation Support
    1. 12.1 Receiving Notification of Documentation Updates
    2. 12.2 サポート・リソース
    3. 12.3 Trademarks
    4. 12.4 Electrostatic Discharge Caution
    5. 12.5 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Application Curves

GUID-440A86DB-C0F2-4399-A056-9DD87D8B8F5E-low.gifFigure 9-2 Near End Eye Measurement Set-Up With Pre-Channel Cable
GUID-86FC30E6-7E09-413E-8FD2-C623639D426E-low.pngFigure 9-3 2 Meter Pre-Channel Without TUSB217A
GUID-EA3744A2-8753-4F32-B11B-A3E2BB47180E-low.pngFigure 9-5 2 Meter Pre-Channel With TUSB217A BOOST=0 RX_SEN=HIGH
GUID-122934E1-BD07-4217-BCED-BDFC0A148F3E-low.pngFigure 9-7 3 Meter Pre-Channel With TUSB217A BOOST=0 RX_SEN=HIGH
GUID-117BB206-6F58-49C2-9949-E3019018A0C1-low.pngFigure 9-9 5 Meter Pre-Channel With TUSB217A BOOST=1 RX_SEN=MED
GUID-D3BF0115-32A2-43C7-8052-21DBE9CA9111-low.pngFigure 9-4 2 Meter Pre-Channel With TUSB217A BOOST=1 RX_SEN=MED
GUID-7D2BA584-77BE-457F-AA66-DC66C861586D-low.pngFigure 9-6 3 Meter Pre-Channel Without TUSB217A
GUID-539B35C7-45FE-4A07-8D15-46075D2A00E9-low.pngFigure 9-8 5 Meter Without TUSB217A
GUID-196E17F3-B8C8-45D9-A64D-76E741998EA9-low.pngFigure 9-10 5 Meter Pre-Channel With TUSB217A BOOST=2 RX_SEN=MED
GUID-E9F01965-81A3-488B-900E-0BB8070DB7D0-low.gifFigure 9-11 Near End Eye Measurement Set-Up With Post-Channel Cable
GUID-3880D391-3694-4A42-974C-0A8707FFEE79-low.pngFigure 9-12 6 Inches Post Channel Without TUSB217A
GUID-6DD23D2C-388C-4038-9E3B-B82604D1A4E9-low.pngFigure 9-14 1 Meter Post-Channel Without TUSB217A
GUID-454289A9-F89A-4DDC-A347-E323FA0B2DAC-low.pngFigure 9-16 1 Meter Post-Channel With TUSB217A BOOST=0 RX_SEN=HIGH
GUID-6BC91F64-49A5-4112-9F04-85695A08BB85-low.pngFigure 9-18 2 Meter Post-Channel With TUSB217A BOOST=1 RX_SEN=MED
GUID-8A758ED2-EC59-4662-BE5B-2E7FB1ECF9E7-low.pngFigure 9-20 4 Meter Post-Channel Without TUSB217A
GUID-8C73FED6-A1BF-4800-B048-A02EDC56D594-low.pngFigure 9-13 6 Inches Post-Channel With TUSB217A BOOST=0 RX_SEN=HIGH
GUID-2B37F4E9-7063-41EF-A97E-4FDED25A3048-low.pngFigure 9-15 1 Meter Post-Channel With TUSB217A BOOST=0 RX_SEN=MED
GUID-E98F3E15-4820-471A-AE3A-4E4FFF830A9C-low.pngFigure 9-17 2 Meter Post-Channel Without TUSB217A
GUID-D700B282-0BD8-4BB2-B304-2CCC7D81A088-low.pngFigure 9-19 2 Meter Post-Channel With TUSB217A BOOST=1 RX_SEN=HIGH
GUID-EAD089CC-17C4-4CE5-BD6D-D07B17EE2886-low.pngFigure 9-21 4 Meter Post-Channel With TUSB217A BOOST=2 RX_SEN=MED