JAJSOG3 December   2023 UCC28750

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Timing Requirements
    8. 6.8 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Detailed Pin Descriptions
      1. 7.3.1 VDD - Input Bias
      2. 7.3.2 DRV - Gate Drive Out
      3. 7.3.3 CS - Current Sensing
      4. 7.3.4 FB - Feedback
      5. 7.3.5 FLT - Fault
      6. 7.3.6 GND - Ground Return
    4. 7.4 Feature Description
      1. 7.4.1 Soft Start
      2. 7.4.2 Control Law
      3. 7.4.3 Frequency Dithering
      4. 7.4.4 Fault Protections
        1. 7.4.4.1 VDD Overvoltage and Undervoltage Lockout
        2. 7.4.4.2 Internal Overtemperature Protection
        3. 7.4.4.3 Output Overpower Protection
        4. 7.4.4.4 Output Short-Circuit Protection
        5. 7.4.4.5 FLT Pin Protections
      5. 7.4.5 Slope Compensation
    5. 7.5 Device Functional Modes
      1. 7.5.1 Off
      2. 7.5.2 Startup
      3. 7.5.3 On
      4. 7.5.4 Fault
      5. 7.5.5 Disabled
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Application
      2. 8.2.2 Design Requirements
      3. 8.2.3 Detailed Design Procedure
        1. 8.2.3.1 Input Bulk Capacitance with Minimum Bulk Voltage
        2. 8.2.3.2 Transformer Turns Ratio and Inductance
        3. 8.2.3.3 Current Sense and Slope Compensation Network
        4. 8.2.3.4 Output Capacitors
        5. 8.2.3.5 VDD Capacitance, CVDD
      4. 8.2.4 Application Performance Plots
        1. 8.2.4.1 Startup
        2. 8.2.4.2 Load Transients
        3. 8.2.4.3 Q1 Drain Voltage Evaluation
      5. 8.2.5 What to Do and What Not to Do
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
      1. 9.1.1 Related Documentation
    2. 9.2 ドキュメントの更新通知を受け取る方法
    3. 9.3 サポート・リソース
    4. 9.4 Trademarks
    5. 9.5 静電気放電に関する注意事項
    6. 9.6 用語集
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Timing Requirements

Unless otherwise specified, VDD = 20 V; VFB = 2.3 V; VFLT = 2 V; TA = 25 ℃; CDRV = 1000 pF
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
PROTECTIONS(1)
VDDdelay(ovlo) Switching cycles required to trigger over-voltage lockout VVDD = 29 V
VFB = 2.3 V
3 cycles
topp Duration that VFB must be at or above the Vopp threshold to trigger the fault VFB = 3 V, Duty cycle > 60 % 80 85 90 ms
tbrownout Amount of time the brownout threshold must be active to trigger the brownout fault VFLT = 1.3 V 44 ms
FLTdelay(ovp) Delay from the time the FLT over-voltage fault occurs to when the controller stops switching VFLT = 4.1 V 3 cycles
FLTdelay(tsd) Delay from the time the FLT thermal shutdown fault occurs to when the controller stops switching VFLT = 0.9 V 32 cycles
CSoscp(delay) Number of cycles of output short circuit condition to trigger the fault VCS ≥ VCS(limit) during tleb 8 cycles
Tshut(delay) Number of switching cycles once internal temperature reaches threshold to trigger fault TJ > 160 °C 32 cycles
Specified by design, not production tested.